Effect of Orientation to the Gravitational Vertical on Nystagmus Following Rotation About A Horizontal Axis
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Following clockwise rotation at 60°/sec about a horizontal cephalo-caudal axis the rate of decay of nystagmic eye movements, produced by an impulsive deceleration, was significantly greater than when the axis of rotation was vertical. The direction of the gravitational acceleration when normal to the axis of rotation had no consistent effect on the time constant of decay, though the angular velocity of nystagmus was greater in the 0° and 90° positions than at 180° and 270° and accounted for the larger nystagmus output in the former positions. Hypothetical mechanisms by which a linear acceleration may modify post-rotational responses are discussed.Nach Rechtsdrehung von 60°/sec urn einc horizontalc cephalo-caudale Achse war die Abnahmerate nystagmischer Augenbcwegungen, hervorgerufen durch plötzliches Abbremsen, wesentlich grosser als nach Drehung um eine vertikale Achsc. Die Richtung der Gravitationsbeschleunigung im Winkel von 90° zur horizontalen Drehachse hatte keine bemerkenswerte Auswirkung auf die Zeitkonstante der Abnahme des Nystagmus, obgleicli die Winkelgeschwindigkeit in den Positionen von 0° und 90° grösser war als in den Positionen von 180° und 270°, weshalb sie für die grössere Gesamtamplitude des Nystagmus in den erstgenannten Stellungen verantwortlich zu machen ist. Es werden hypothetische Mechanismen besprochen, bei denen eine lineare Beschleunigung post-rotationale Reaktionen verändern kann.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Interaction of linear and angular accelerations on vestibular receptors in man.
Benson, A. J., & Ma, B. (1966) · PubMed · Cited by 166
Self-citationFrog Labyrinthine Efferent Impulses
Schmidt, R. S. (1963) · Acta Oto-Laryngologica · doi:10.3109/00016486309127679 · Cited by 107
Arousal Effects and Nystagmus During Prolonged Constant Angular Acceleration
Collins, W. E., & Guedry, F. E. (1962) · Acta Oto-Laryngologica · doi:10.3109/00016486209126954 · Cited by 67
Vestibular Efferent System:Electrophysiological Research
Sala, O. (1965) · Acta Oto-Laryngologica · doi:10.3109/00016486509124566 · Cited by 44
Lansberg, M. P., Guedry, F. E., & Graybiel, A. (1964) · PsycEXTRA Dataset · doi:10.1037/e407172004-001 · Cited by 11
Cited by
The Head-Neck Sensory Motor System
(1992) · doi:10.1093/acprof:oso/9780195068207.001.0001 · Cited by 331
A model of the nystagmus induced by off vertical axis rotation
Hain, T. C. (1986) · Biological Cybernetics · doi:10.1007/bf00318429 · Cited by 214
“Tilts of the head supine or into the lateral (roll 90 deg) positions also lower the time constant (Benson and Bodin 1966b; Schrader et al. 1985a, b). If the perrotatory response is elicited by barbecue rotation, the time constant is 8.5 whether the head is stopped supine, prone or in either lateral position ( Benson a…”
BackgroundInfluentialModification of the Response to Angular Accelerations by Linear Accelerations
Benson, A. J. (1974) · Handbook of Sensory Physiology · doi:10.1007/978-3-642-65920-1_6 · Cited by 189
Self-citationThe vestibulo-ocular reflex of the squirrel monkey during eccentric rotation and roll tilt
Merfeld, D., & Young, L. (1995) · Experimental Brain Research · doi:10.1007/bf00241361 · Cited by 160
Lackner, J. R., & DiZio, P. (1992) · The Head-Neck Sensory Motor System · doi:10.1093/acprof:oso/9780195068207.003.0033 · Cited by 11
Metadata
- Authors
- Benson, A. J., & Bodin, M. A.
- Venue
- Acta Oto-Laryngologica
- Publisher
- Informa UK Limited
- Published
- 1966-01
- Volume
- 61
- Issue
- 1-6
- Pages
- 517-526
- ISSN
- 0001-6489 (ISSN-L)
- 1651-2251
- OpenAlex
- W1974380326
- Cited by
- 165
- References
- 5
- FWCI
- 2.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.