Spatiotemporal Changes of Eeg Activity During Waking-Sleeping Transition Period
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
To evaluate the spatiotemporal changes of EEG during waking-sleeping transition or hypnagogic period, spectral analysis of the five scalp EEG on the midline (Fpz, Fz, Cz, Pz and Oz) referenced to the left ear lobe was carried out on seven young male subjects. Power spectra from consecutive samples of 5.12 sec period with 0.2 Hz resolution were studied from 10 min before the manually scored stage 1 onset to 30 min after the onset of stage 1. The average power spectra over 1 min segments and corresponding coefficient of variation (CV) were determined for the frequency bands of delta (1-3 Hz), theta (4-7 Hz), alpha (8-12 Hz), sigma (13-15 Hz) and beta (16-19 Hz). The latency score was defined as the time elapsed from the onset of stage 1 to the first epoch when the frequency band power, using the ANOVA significantly increased (or decreased) in comparison with the average level at the onset of stage 1. Median latency scores for each band were similar to the Cz scores, with a ranking, from early to late, of: alpha (2 min), theta (3 min), delta (5 min) and sigma (5 min). Significant change was not observed on the beta band activity. In terms of the EEG areas, the shortest latency was found in the theta band activity of the Fz EEG (2 min), and the longest was the sigma band activity of the Fpz and Oz EEG (8 min). The average stage 2 latency was 3.5 min when it was measured as time elapsed between the onset of stage 1 and 2. The average curves of delta, theta and alpha band CVs, started to increase just before or immediately after stage 1 onset and continued to increase for about 10 min. If the increased CV or unsteadiness of EEG activity is taken as a characteristic of the hypnagogic period, hypnagogic states may be considered to have continued until about 10 min after the stage 1 onset. Delta-theta activity showed a rapid rise in power after the onset of stage 1 for all areas. Delta power at the occipital, however, increased more gradually, and consistently remained at a lower level. The differences of delta power between Oz and other four electrode sites became clear at 7 min after the onset of stage 1. These regional differences may reflect the termination of hypnagogic effects.(ABSTRACT TRUNCATED AT 400 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A cluster analysis of insomnia
Hauri, P. J. (1983) · Sleep · doi:10.1093/sleep/6.4.326 · Cited by 90
Cited by
Functional topography of the human nonREM sleep electroencephalogram
Finelli, L. A., Borbély, A. A., & Achermann, P. (2001) · European Journal of Neuroscience · doi:10.1046/j.0953-816x.2001.01597.x · Cited by 349
Lapse in alertness: coherence of fluctuations in performance and EEG spectrum
Makeig, S., & Inlow, M. (1993) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(93)90064-3 · Cited by 338
Ogilvie, R. D. (2001) · Sleep Medicine Reviews · doi:10.1053/smrv.2001.0145 · Cited by 310
Individual 'Fingerprints' in Human Sleep EEG Topography
Finelli, L. (2001) · Neuropsychopharmacology · doi:10.1016/s0893-133x(01)00320-7 · Cited by 184
“Early reports that the location of the recording electrodes affects the pattern of the sleep EEG (Findji et al. 1981; Buchsbaum et al. 1982; Hori 1985) were reexamined by using contemporary methods of quantitative EEG analysis.”
BackgroundMethodSiclari, F., Bernardi, G., Riedner, B. A., LaRocque, J. J., Benca, R. M., & Tononi, G. (2014) · Sleep · doi:10.5665/sleep.4070 · Cited by 181
Topographical EEG changes and the hypnagogic experience.
Hori, T., Hayashi, M., & Morikawa, T. (1994) · Sleep onset: Normal and abnormal processes. · doi:10.1037/10166-014 · Cited by 179
Self-citationBrain topography of the human sleep EEG: antero-posterior shifts of spectral power
Werth, E., Achermann, P., & Borbély, A. A. (1996) · NeuroReport · doi:10.1097/00001756-199612200-00025 · Cited by 169
Brain dynamics during the sleep onset transition: an EEG source localization study
Fernandez Guerrero, A., & Achermann, P. (2019) · Neurobiology of Sleep and Circadian Rhythms · doi:10.1016/j.nbscr.2018.11.001 · Cited by 35
“Frequency specific systematic EEG changes during wake-sleep transitions have been reported (Hori, 1985; Merica and Gaillard, 1992, Ogilvie, 2001).”
Metadata
- Authors
- Hori, T.
- Venue
- International Journal of Neuroscience
- Publisher
- Informa UK Limited
- Published
- 1985-01
- Volume
- 27
- Issue
- 1-2
- Pages
- 101-114
- ISSN
- 0020-7454 (ISSN-L)
- 1543-5245
- OpenAlex
- W2068765738
- Cited by
- 55
- References
- 1
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.