Studies on renal tubular protein reabsorption: Partial and near complete inhibition by certain amino acids
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Urinary excretion of albumin, free light chains of immunoglobulins and beta-2-microglobulin was measured after injection of certain amino acids and derivatives. Substances with a positively charged group located terminally in the molecule (ornithine, lysine, arginine, and the almost not metabolized epsilon-amino-caproic acid, and Cyclocaprone) proved to inhibit instantaneously the tubular protein reabsorption. Lysine is the most effective molecule tested. We hypothesize that the initial event in the normal tubular protein reabsorption is a binding between a free positive amino- or guanidino-group in the protein molecule and a negative site on the tubular cell surface. In an attempt to achieve complete inhibition of tubular protein reabsorption, large doses of lysine were injected intravenously. The maximal protein clearance rose from the exceedingly low baseline excretion to values probably representing near complete inhibition of protein reabsorption. The minimal value of albumin concentration in the glomerular filtrate was calculated to 2.6 mg/l.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantitative estimation of proteins by electrophoresis in agarose gel containing antibodies
Laurell, C.-B. (1966) · Analytical Biochemistry · doi:10.1016/0003-2697(66)90246-6 · Cited by 4,401
Peterson, P. A., Evrin, P.-E., & Berggård, I. (1969) · Journal of Clinical Investigation · doi:10.1172/jci106083 · Cited by 540
The renal handling of low molecular weight proteins
Waldmann, T. A., Strober, W., & Mogielnicki, R. P. (1972) · Journal of Clinical Investigation · doi:10.1172/jci107023 · Cited by 284
Radioimmunoassay of β2-Microglobulin in Human Biological Fluids
Evrin, P. E., Peterson, P. A., Wide, L., & Berggard, I. (1971) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365517109095721 · Cited by 253
Radioimmunoassay for Urinary Albumin Using a Single Antibody
Miles, D. W., Mogensen, C. E., & Gundersen, H. J. G. (1970) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365517009049206 · Cited by 250
Self-citationProteins in Normal and Pathological Urine.
(1971) · Annals of Internal Medicine · doi:10.7326/0003-4819-74-1-154_2 · Cited by 238
Weiss, L. (1969) · International review of cytology · doi:10.1016/s0074-7696(08)61634-4 · Cited by 155
Johansson, B. G., & Ravnskov, U. (1972) · Scandinavian Journal of Urology and Nephrology · doi:10.3109/00365597209132096 · Cited by 79
Cited by
Microalbuminuria as a predictor of clinical diabetic nephropathy
Mogensen, C. E. (1987) · Kidney International · doi:10.1038/ki.1987.50 · Cited by 544
Self-citationRenal albumin absorption in physiology and pathology
Birn, H., & Christensen, E. I. (2006) · Kidney International · doi:10.1038/sj.ki.5000141 · Cited by 381
Rolleman, E., Valkema, R., de Jong, M., Kooij, P., & Krenning, E. (2003) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-002-0982-3 · Cited by 321
Behr, T. M., Goldenberg, D. M., & Becker, W. (1998) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590050216 · Cited by 274
Microalbuminuria, blood pressure and diabetic renal disease: origin and development of ideas
Mogensen, C. E. (1999) · Diabetologia · doi:10.1007/s001250051151 · Cited by 274
Self-citation
Metadata
- Authors
- Mogensen, C. E., & Sølling, K.
- Venue
- Scandinavian Journal of Clinical and Laboratory Investigation
- Publisher
- Informa UK Limited
- Published
- 1977-01
- Volume
- 37
- Issue
- 6
- Pages
- 477-486
- ISSN
- 0036-5513 (ISSN-L)
- 1502-7686
- OpenAlex
- W2087812051
- Cited by
- 233
- References
- 8
- FWCI
- 5.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.