The DOI matches its Crossref record.
Analytical goals for the acceptance of common reference intervals for laboratories throughout a geographical area
Abstract
Analytical goals required for the successful transfer of reference intervals between laboratories within a specified limited geographical area, with a population homogeneous for the quantities, are presented. Diagrams are shown which allow the investigation of the influence of analytical imprecision and bias, both separately and in combination, on the percentage of the population outside each reference limit. Figures to evaluate the effect of population sample size on the size of confidence interval around each reference limit are combined with the diagrams for analytical imprecision and bias. The maximum acceptable percentage of the population outside the limit for the 0.90 confidence interval of each of the means +/- 1.96 s reference limits is 4.6% for a population sample size of 120. Based on this, the maximum acceptable imprecision, with no bias, is 0.6 of the total biological standard deviation (sB) and the maximum acceptable bias, with no imprecision, is 0.25 sB.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Proposals for Setting Generally Applicable Quality Goals Solely Based on Biology
Fraser, C. G., Petersen, P. H., Libeer, J.-C., & Ricos, C. (1997) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/000456329703400103 · Cited by 370
Self-citationReference intervals: the way forward
Ceriotti, F., Hinzmann, R., & Panteghini, M. (2009) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/acb.2008.008170 · Cited by 199
Analytical performance characteristics should be judged against objective quality specifications
Fraser, C. G., & Petersen, P. H. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.3.321 · Cited by 194
Self-citationReference intervals for hemoglobin A1c in pregnant women: data from an Italian multicenter study
Mosca, A., Paleari, R., Dalfrà, M. G., Di Cianni, G., Cuccuru, I., Pellegrini, G., Malloggi, L., Bonomo, M., Granata, S., Ceriotti, F., et al. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2005.064899 · Cited by 161
Quality control review: implementing a scientifically based quality control system
Westgard, J. O., & Westgard, S. A. (2016) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/0004563215597248 · Cited by 109
Metadata
- Authors
- Gowans, E. M. S., Petersen, P. H., Blaabjerg, O., & Hørder, M.
- Venue
- Scandinavian Journal of Clinical and Laboratory Investigation
- Publisher
- Informa UK Limited
- Published
- 1988-01
- Volume
- 48
- Issue
- 8
- Pages
- 757-764
- ISSN
- 0036-5513 (ISSN-L)
- 1502-7686
- OpenAlex
- W2157114400
- Cited by
- 162
- References
- 0
- FWCI
- 1.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Analytical goals for the acceptance of common reference intervals for laboratories throughout a geographical area. https://app.cochat.ai/papers/10.3109/00365518809088757
- The paper
- Gowans, E. M. S., Petersen, P. H., Blaabjerg, O., & Hørder, M. (1988). Analytical goals for the acceptance of common reference intervals for laboratories throughout a geographical area. Scandinavian Journal of Clinical and Laboratory Investigation. https://doi.org/10.3109/00365518809088757
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.