The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Outflow resistance of enucleated human eyes at two different perfusion pressures and different extents of trabeculotomy
Abstract
Aqueous outflow resistance of enucleated human eyes was measured at 7 and 25 mm Hg before and after partial and complete (12 clock hours) internal trabeculotomy. Following complete trabeculotomy, 71% of the resistance was eliminated at 25 mm Hg while only 49% was eliminated at 7 mm Hg. In contrast to published findings in eyes with intact trabecular meshwork where the resistance increased with increasing IOP (1), following complete trabeculotomy, the resistance decreased 2% per mm Hg with increasing IOP. Experiments with trabeculotomy limited to part of the circumference showed that a one hour trabeculotomy produced 41% (25 mm Hg) to 60% (7 mm Hg) of the effect of a twelve hour trabeculotomy. The results indicate that a surprisingly high fraction of aqueous outflow resistance resides in the distal aspects of the outflow system at normal IOP, and that this distal resistance drops as IOP is increased.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Experimental Aqueous Perfusion in Enucleated Human Eyes
GRANT, W. M. (1963) · Archives of Ophthalmology · doi:10.1001/archopht.1963.00960040789022 · Cited by 538
Self-citationThe role of Schlemm's canal in aqueous outflow from the human eye.
Johnson, M., & Kamm, R. D. (1983) · PubMed · Cited by 175
Self-citationInfluence of intraocular pressure and trabeculotomy on aqueous outflow in enucleated monkey eyes.
Ellingsen, B. A., & Grant, W. M. (1971) · PubMed · Cited by 59
Self-citation
Cited by
Micro-invasive glaucoma surgery: current perspectives and future directions
Saheb, H., & Ahmed, I. I. K. (2012) · Current Opinion in Ophthalmology · doi:10.1097/icu.0b013e32834ff1e7 · Cited by 633
Extracellular matrix in the trabecular meshwork
Acott, T. S., & Kelley, M. J. (2008) · Experimental Eye Research · doi:10.1016/j.exer.2008.01.013 · Cited by 503
‘What controls aqueous humour outflow resistance?’
Johnson, M. (2006) · Experimental Eye Research · doi:10.1016/j.exer.2005.10.011 · Cited by 482
Self-citationAqueous outflow - A continuum from trabecular meshwork to episcleral veins
Carreon, T., van der Merwe, E., Fellman, R. L., Johnstone, M., & Bhattacharya, S. K. (2017) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2016.12.004 · Cited by 312
Pressures in the juxtacanalicular tissue and Schlemm's canal in monkeys
Mäepea, O., & Bill, A. (1992) · Experimental Eye Research · doi:10.1016/0014-4835(92)90151-h · Cited by 290
Metadata
- Authors
- Rosenquist, R., Epstein, D., Melamed, S., Johnson, M., & Grant, W. M.
- Venue
- Current Eye Research
- Publisher
- Informa UK Limited
- Published
- 1989-01
- Volume
- 8
- Issue
- 12
- Pages
- 1233-1240
- ISSN
- 0271-3683 (ISSN-L)
- 1460-2202
- OpenAlex
- W2029346354
- Cited by
- 279
- References
- 3
- FWCI
- 0.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Outflow resistance of enucleated human eyes at two different perfusion pressures and different extents of trabeculotomy. https://app.cochat.ai/papers/10.3109/02713688909013902
- The paper
- Rosenquist, R., Epstein, D., Melamed, S., Johnson, M., & Grant, W. M. (1989). Outflow resistance of enucleated human eyes at two different perfusion pressures and different extents of trabeculotomy. Current Eye Research. https://doi.org/10.3109/02713688909013902
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.