Lipophilicity influence on conjunctival drug penetration in the pigmented rabbit: A comparison with corneal penetration
The DOI matches its Crossref record.
Abstract
The influence of lipophilicity on the conjunctival penetration of beta blockers in the pigmented rabbit was investigated and compared with that on corneal penetration. The beta blockers were hydrophilic sotalol, atenolol, nadolol, pindolol, and acebutolol; lipophilic metoprolol, timolol, oxprenolol, levobunolol, labetalol, and alprenolol; and the very lipophilic propranolol and betaxolol. Drug penetration was evaluated by using the isolated pigmented rabbit conjunctiva and cornea in the modified Ussing chamber and was monitored by reversed phase HPLC. The conjunctiva was more permeable to all the beta blockers than was the cornea. A sigmoidal relationship, rather than the familiar parabolic relationship, best described the influence of lipophilicity on both conjunctival and corneal drug penetration. The ratio of corneal to conjunctival permeability coefficients was most sensitive to changes in log PC within the region of 1.5 and 2.5. Outside of this region, the ratio was relatively independent of changes in lipophilicity. For several beta blockers, their intrinsic sympathomimetic activity may play a minor role in influencing their conjunctival and corneal penetration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Permeability of cornea, sclera, and conjunctiva: A literature analysis for drug delivery to the eye
Prausnitz, M. R., & Noonan, J. S. (1998) · Journal of Pharmaceutical Sciences · doi:10.1021/js9802594 · Cited by 627
Vesicular systems in ocular drug delivery: an overview
Kaur, I. P., Garg, A., Singla, A. K., & Aggarwal, D. (2004) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2003.09.016 · Cited by 450
Topical and systemic drug delivery to the posterior segments
HUGHES, P., OLEJNIK, O., CHANGLIN, J., & WILSON, C. (2005) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2005.09.004 · Cited by 400
Ocular absorption following topical delivery
Järvinen, K., Järvinen, T., & Urtti, A. (1995) · Advanced Drug Delivery Reviews · doi:10.1016/0169-409x(95)00010-5 · Cited by 358
Penetration Enhancers and Ocular Bioadhesives: Two New Avenues for Ophthalmic Drug Delivery
Kaur, I. P., & Smitha, R. (2002) · Drug Development and Industrial Pharmacy · doi:10.1081/ddc-120002997 · Cited by 305
Cyclodextrins in ophthalmic drug delivery
Loftssona, T. (1999) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(98)00055-6 · Cited by 305
Cell culture models of the ocular barriers
Hornof, M., Toropainen, E., & Urtti, A. (2005) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2005.01.009 · Cited by 300
Recent Advances in Ophthalmic Drug Delivery
Kompella, U. B., Kadam, R. S., & Lee, V. H. (2010) · Therapeutic Delivery · doi:10.4155/tde.10.40 · Cited by 285
Self-citationBiopharmaceutical Considerations In Topical Ocular Drug Delivery
Davies, N. M. (2000) · Clinical and Experimental Pharmacology and Physiology · doi:10.1046/j.1440-1681.2000.03288.x · Cited by 267
Minimizing systemic absorption of topically administered ophthalmic drugs
Urtti, A., & Salminen, L. (1993) · Survey of Ophthalmology · doi:10.1016/0039-6257(93)90141-s · Cited by 265
Permeability of Retinal Pigment Epithelium: Effects of Permeant Molecular Weight and Lipophilicity
Pitka¨nen, L., Ranta, V.-P., Moilanen, H., & Urtti, A. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-1051 · Cited by 261
“molecular size (molecular masses typically between 250 and 320 Da) and ionization constant (bases with pKa 9), but their lipophilicity varies over a wide range.(16,17)”
BackgroundMethodLiposomes in topical ophthalmic drug delivery: an update
Agarwal, R., Iezhitsa, I., Agarwal, P., Abdul Nasir, N. A., Razali, N., Alyautdin, R., & Ismail, N. M. (2016) · Drug Delivery · doi:10.3109/10717544.2014.943336 · Cited by 214
“1 10 6 cm/s) in the isolated rabbit cornea (Wang et al., 1991; Prausnitz & Noonan, 1998).”
BackgroundInfluentialDrug metabolism and pharmacokinetics
Benedetti, M. S., Whomsley, R., Poggesi, I., Cawello, W., Mathy, F.-X., Delporte, M.-L., Papeleu, P., & Watelet, J.-B. (2009) · Drug Metabolism Reviews · doi:10.1080/10837450902891295 · Cited by 201
“, 1991) and a sigmoidal (Wang et al., 1991) relationship have been found to describe the influence of lipophilicity on corneal drug permeability.”
BackgroundInfluentialHosoya, K.-I., Lee, V. H. L., & Kim, K.-J. (2005) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2004.12.007 · Cited by 194
Self-citationCyclodextrins in eye drop formulations: enhanced topical delivery of corticosteroids to the eye
Loftsson, T., & Stefánsson, E. (2002) · Acta Ophthalmologica Scandinavica · doi:10.1034/j.1600-0420.2002.800205.x · Cited by 173
“However, they must also be somewhat lipidsoluble in order to penetrate the lipophilic corneal epithelium, through the corneal stroma and the lipophilic endothelium into the aqueous humour (Ahmed et al. 1987; Wang et al. 1991).”
BackgroundModel of transient drug diffusion across cornea
Zhang, W., Prausnitz, M. R., & Edwards, A. (2004) · Journal of Controlled Release · doi:10.1016/j.jconrel.2004.07.001 · Cited by 166
“[18], who measured the conjunctival-to-corneal permeability ratio of hydrophilic h-blockers as 20, and by other investigators who reported values in the range of 14–25 [12,16,19].”
BackgroundCannabinoids in the treatment of glaucoma
Järvinen, T., Pate, D. W., & Laine, K. (2002) · Pharmacology & Therapeutics · doi:10.1016/s0163-7258(02)00259-0 · Cited by 161
Transscleral drug delivery to the posterior eye: Prospects of pharmacokinetic modeling
Ranta, V.-P., & Urtti, A. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.07.025 · Cited by 160
A primary culture model of rabbit conjunctival epithelial cells exhibiting tight barrier properties
Saha, P., Kim, K.-J., & Lee, V. H. L. (1996) · Current Eye Research · doi:10.3109/02713689608995151 · Cited by 73
Self-citationNanoparticulate drug delivery to the retina
Li, Q., Weng, J., Wong, S. N., Thomas Lee, W. Y., & Chow, S. F. (2021) · Molecular Pharmaceutics · doi:10.1021/acs.molpharmaceut.0c00224 · Cited by 59
Pescina, S., Grolli Lucca, L., Govoni, P., Padula, C., Del Favero, E., Cantù, L., Santi, P., & Nicoli, S. (2019) · Pharmaceutics · doi:10.3390/pharmaceutics11090476 · Cited by 38
Barlow, N. E., Bolognesi, G., Haylock, S., Flemming, A. J., Brooks, N. J., Barter, L. M. C., & Ces, O. (2017) · Scientific Reports · doi:10.1038/s41598-017-17883-0 · Cited by 23
Metadata
- Authors
- Wang, W., Sasaki, H., Chien, D.-S., & Lee, V. H. L.
- Venue
- Current Eye Research
- Publisher
- Informa UK Limited
- Published
- 1991-01
- Volume
- 10
- Issue
- 6
- Pages
- 571-579
- ISSN
- 0271-3683 (ISSN-L)
- 1460-2202
- OpenAlex
- W2069809327
- Cited by
- 142
- References
- 0
- FWCI
- 3.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.