CoChat

Optimising Imaging Parameters for Post Mortem MR Imaging of the Human Brain

Open access
Blamire, A. M., Rowe, J. G., Styles, P., McDonald, B. · 1999 · Acta Radiologica
Cited by 70

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Purpose: MR imaging of post mortem brains has the potential to yield volumetric information and define the extent of structural changes prior to pathological examination. Although standard T2-weighted clinical imaging sequences have been used for the examination of formalin-fixed brains, these protocols may not yield optimum contrast. We examined the effect of varying durations of formalin fixation on the transverse relaxation time (T2) and the tissue spin density. Material and Methods: Three post mortem brains were examined weekly during formalin fixation from the unfixed state to 35 days fixation. Standard MR spin-echo imaging was used at 5 echo times (20–100 ms) to calculate transverse relaxation time (T2) and spin density. Results: T2 decreased significantly (ANOVA, p<0.001) in both grey and white matter by 7 days fixation and there was a further (but non-significant) trend towards lower values between 7 and 35 days. Grey and white matter T2 times converged with fixation. Conversely, the grey to white matter spin density ratio increased from 1.19±0.01 to 1.54±0.06 over five weeks of fixation. Conclusion: Our results suggest that spin density-weighted imaging sequences would provide improved grey to white matter contrast over T2-weighted sequences.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3109/02841859909175593

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 70

Metadata

Authors
Blamire, A. M., Rowe, J. G., Styles, P., & McDonald, B.
Venue
Acta Radiologica
Published
1999-11
Volume
40
Issue
6
Pages
593-597
ISSN
  • 0284-1851 (ISSN-L)
  • 1600-0455
OpenAlex
W2016800756
Cited by
70
References
1
FWCI
0.91
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.