Comparison of onboard low-field magnetic resonance imaging versus onboard computed tomography for anatomy visualization in radiotherapy
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Onboard magnetic resonance imaging (OB-MRI) for daily localization and adaptive radiotherapy has been under development by several groups. However, no clinical studies have evaluated whether OB-MRI improves visualization of the target and organs at risk (OARs) compared to standard onboard computed tomography (OB-CT). This study compared visualization of patient anatomy on images acquired on the MRI-(60)Co ViewRay system to those acquired with OB-CT. MATERIAL AND METHODS: Fourteen patients enrolled on a protocol approved by the Institutional Review Board (IRB) and undergoing image-guided radiotherapy for cancer in the thorax (n = 2), pelvis (n = 6), abdomen (n = 3) or head and neck (n = 3) were imaged with OB-MRI and OB-CT. For each of the 14 patients, the OB-MRI and OB-CT datasets were displayed side-by-side and independently reviewed by three radiation oncologists. Each physician was asked to evaluate which dataset offered better visualization of the target and OARs. A quantitative contouring study was performed on two abdominal patients to assess if OB-MRI could offer improved inter-observer segmentation agreement for adaptive planning. RESULTS: In total 221 OARs and 10 targets were compared for visualization on OB-MRI and OB-CT by each of the three physicians. The majority of physicians (two or more) evaluated visualization on MRI as better for 71% of structures, worse for 10% of structures, and equivalent for 14% of structures. 5% of structures were not visible on either. Physicians agreed unanimously for 74% and in majority for > 99% of structures. Targets were better visualized on MRI in 4/10 cases, and never on OB-CT. CONCLUSION: Low-field MR provides better anatomic visualization of many radiotherapy targets and most OARs as compared to OB-CT. Further studies with OB-MRI should be pursued.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
Warfield, S. K., Zou, K. H., & Wells, W. M. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.828354 · Cited by 2,335
Statistical validation of image segmentation quality based on a spatial overlap index1
Zou, K. H., Warfield, S. K., Bharatha, A., Tempany, C. M. C., Kaus, M. R., Haker, S. J., Wells, W. M., Jolesz, F. A., & Kikinis, R. (2004) · Academic Radiology · doi:10.1016/s1076-6332(03)00671-8 · Cited by 1,849
The ViewRay System: Magnetic Resonance–Guided and Controlled Radiotherapy
Mutic, S., & Dempsey, J. F. (2014) · Seminars in Radiation Oncology · doi:10.1016/j.semradonc.2014.02.008 · Cited by 915
Self-citationBarkhausen, J., Ruehm, S. G., Goyen, M., Buck, T., Laub, G., & Debatin, J. F. (2001) · Radiology · doi:10.1148/radiology.219.1.r01ap12264 · Cited by 380 · cited 1×
“Volumetric axial-plane MR images were acquired for each patient using a fast gradient echo sequence (TrueFISP or turbo FLASH) [10] with parallel imaging techniques, as set by the manufacturer.”
MethodMagnetic resonance imaging (MRI): considerations and applications in radiotherapy treatment planning
Khoo, V. S., Dearnaley, D. P., Finnigan, D. J., Padhani, A. R., Tanner, S. F., & Leach, M. O. (1997) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(96)01866-x · Cited by 362
Fallone, B. G., Murray, B., Rathee, S., Stanescu, T., Steciw, S., Vidakovic, S., Blosser, E., & Tymofichuk, D. (2009) · Medical Physics · doi:10.1118/1.3125662 · Cited by 325 · cited 1×
“Research teams in the Netherlands [4] and Canada [5] are each developing systems integrating linear accelerators with onboard MRI.”
BackgroundRadiotherapy treatment planning of prostate cancer using magnetic resonance imaging alone
Lee, Y. (2003) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(02)00440-1 · Cited by 227
Characterization, prediction, and correction of geometric distortion in MR images
Baldwin, L., Wachowicz, K., Thomas, S., Rivest, R., & Fallone, B. G. (2007) · Medical Physics · doi:10.1118/1.2402331 · Cited by 219 · cited 1×
“5T onboard MRI may offer some different tradeoffs compared to a low-fi eld system, as it offers higher signal-to-noise, but more technical challenges and is prone to greater geometric distortions due to higher fi eld strength [15].”
BackgroundMRI-based treatment planning for radiotherapy: Dosimetric verification for prostate IMRT
Chen, L., Price, R. A., Wang, L., Li, J., Qin, L., McNeeley, S., Ma, C.-M. C., Freedman, G. M., & Pollack, A. (2004) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2004.05.068 · Cited by 172
MRI simulation for radiotherapy treatment planning
Devic, S. (2012) · Medical Physics · doi:10.1118/1.4758068 · Cited by 158
Standardizing Naming Conventions in Radiation Oncology
Santanam, L., Hurkmans, C., Mutic, S., van Vliet-Vroegindeweij, C., Brame, S., Straube, W. L., Galvin, J. M., Tripuraneni, P., Michalski, J. M., & Bosch, W. R. (2012) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2011.09.054 · Cited by 99
Self-citationJohansson, A., Garpebring, A., Karlsson, M. C. F., Asklund, T., & Nyholm, T. (2013) · Acta Oncologica · doi:10.3109/0284186x.2013.819119 · Cited by 65 · cited 1×
“Research investigating techniques for creating pseudo-CT models from MRI data has been underway, and studies have found this approach to be applicable for MRI-only treatment planning [16,17].”
MethodMagnetic resonance imaging for adaptive cobalt tomotherapy: A proposal
Kron, T., Eyles, D., Schreiner, L. J., & Battista, J. J. (2006) · Journal of Medical Physics · doi:10.4103/0971-6203.29194 · Cited by 34 · cited 1×
“Groups from Melbourne [6] and Cleveland [7] have proposed an alternative design, using a 60 Co treatment approach to simplify the technical considerations.”
Method
Cited by
MR-guidance in clinical reality: current treatment challenges and future perspectives
Corradini, S., Alongi, F., Andratschke, N., Belka, C., Boldrini, L., Cellini, F., Debus, J., Guckenberger, M., Hörner-Rieber, J., Lagerwaard, F. J., et al. (2019) · Radiation Oncology · doi:10.1186/s13014-019-1308-y · Cited by 356
Rudra, S., Jiang, N., Rosenberg, S. A., Olsen, J. R., Roach, M. C., Wan, L., Portelance, L., Mellon, E. A., Bruynzeel, A., Lagerwaard, F., et al. (2019) · Cancer Medicine · doi:10.1002/cam4.2100 · Cited by 350
Self-citationChuong, M. D., Bryant, J., Mittauer, K. E., Hall, M., Kotecha, R., Alvarez, D., Romaguera, T., Rubens, M., Adamson, S., Godley, A., et al. (2021) · Practical Radiation Oncology · doi:10.1016/j.prro.2020.09.005 · Cited by 174
Pathmanathan, A. U., van As, N. J., Kerkmeijer, L. G. W., Christodouleas, J., Lawton, C. A. F., Vesprini, D., van der Heide, U. A., Frank, S. J., Nill, S., Oelfke, U., et al. (2018) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2017.10.020 · Cited by 172
MRI-guided Radiation Therapy: An Emerging Paradigm in Adaptive Radiation Oncology
Otazo, R., Lambin, P., Pignol, J.-P., Ladd, M. E., Schlemmer, H.-P., Baumann, M., & Hricak, H. (2021) · Radiology · doi:10.1148/radiol.2020202747 · Cited by 168
Metadata
- Authors
- Noel, C. E., Parikh, P. J., Spencer, C. R., Green, O. L., Hu, Y., Mutic, S., & Olsen, J. R.
- Venue
- Acta Oncologica
- Published
- 2015-07-24
- Volume
- 54
- Issue
- 9
- Pages
- 1474-1482
- ISSN
- 0284-186X (ISSN-L)
- 1651-226X
- OpenAlex
- W1696976950
- Cited by
- 159
- References
- 14
- FWCI
- 10.71
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.