Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 457

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Sollerman Hand Function Test: A Standardised Method and its Use in Tetraplegic Patients

Sollerman, Christer, Ejeskär, Arvid·1995·Scandinavian Journal of Plastic and Reconstructive Surgery and Hand Surgery

Abstract

A standardised hand function test based on seven of the eight most common hand grips is reported. The test consists of 20 activities of daily living. The test procedure and the method of scoring are described as is our evaluation of the validity and reliability of the test. Fifty-nine tetraplegic patients were evaluated using the test before reconstructive surgery to their hands. The test score correlated well with the accepted international functional classification of the patient's arm (r = 0.76, p < 0.001). The mean test score in the arms of patients lacking sensation was significantly lower than in those with tactile gnosis (O:1-3 compared with OCu:1-3, p < 0.001).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3109/02844319509034334

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

See all 457

Metadata

Authors
Sollerman, C., & Ejeskär, A.
Venue
Scandinavian Journal of Plastic and Reconstructive Surgery and Hand Surgery
Published
1995-01
Volume
29
Issue
2
Pages
167-176
ISSN
0284-4311 (ISSN-L)
OpenAlex
W2022356858
Cited by
457
References
14
FWCI
1.36
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sollerman Hand Function Test: A Standardised Method and its Use in Tetraplegic Patients. https://app.cochat.ai/papers/10.3109/02844319509034334
The paper
Sollerman, C., & Ejeskär, A. (1995). Sollerman Hand Function Test: A Standardised Method and its Use in Tetraplegic Patients. Scandinavian Journal of Plastic and Reconstructive Surgery and Hand Surgery. https://doi.org/10.3109/02844319509034334

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.