The DOI matches its Crossref record.
A surgeon robot prostatectomy—a laboratory evaluation
Abstract
Cet article presente une etude de faisabilite concernant l'assistance d'un robot lors d'une intervention chirurgicale telle que la prostatectomie. L'instrument tranchant est le WELSA et il est adapte sur un robot 6 axis Puma Unimate. Le robot peut se positionner tres precisement sans endommager les tissus adjacents et peut couper plus rapidement qu'un chirurgien, le tout sans se fatiguer
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A review of robotics in surgery
Davies, B. (2000) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411001535309 · Cited by 370
Self-citationThe RAVEN: Design and Validation of a Telesurgery System
Lum, M. J. H., Friedman, D. C. W., Sankaranarayanan, G., King, H., Fodero, K., Leuschke, R., Hannaford, B., Rosen, J., & Sinanan, M. N. (2009) · The International Journal of Robotics Research · doi:10.1177/0278364909101795 · Cited by 264
Kassahun, Y., Yu, B., Tibebu, A. T., Stoyanov, D., Giannarou, S., Metzen, J. H., & Vander Poorten, E. (2016) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-015-1305-z · Cited by 238
Metadata
- Authors
- Davies, B. L., Hibberd, R. D., Coptcoat, M. J., & Wickham, J. E. A.
- Venue
- Journal of Medical Engineering & Technology
- Publisher
- Informa UK Limited
- Published
- 1989-01
- Volume
- 13
- Issue
- 6
- Pages
- 273-277
- ISSN
- 0309-1902 (ISSN-L)
- 1464-522X
- OpenAlex
- W2111188706
- Cited by
- 170
- References
- 0
- FWCI
- 1.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A surgeon robot prostatectomy—a laboratory evaluation. https://app.cochat.ai/papers/10.3109/03091908909016201
- The paper
- Davies, B. L., Hibberd, R. D., Coptcoat, M. J., & Wickham, J. E. A. (1989). A surgeon robot prostatectomy—a laboratory evaluation. Journal of Medical Engineering & Technology. https://doi.org/10.3109/03091908909016201
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.