The i-LIMB Hand and the DMC Plus Hand Compared: A Case Report
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The i-LIMB hand is a novel upper limb myoelectric prosthetic hand with several joints in the fingers and thumb. This study aimed to determine whether this new device had more functionality than a more conventional myoelectric prosthetic hand with only a single joint between the thumb and two fingers. Therefore, a 45-year-old man with a wrist disarticulation used the i-LIMB hand and the widely used Dynamic Mode Control hand (DMC plus hand) in a test procedure that covered all functional levels of the International Classification of Function (ICF). Functional outcomes of the i-LIMB seemed to be lower than or equal to the DMC plus hand. The patient's satisfaction tended to be in favor of the i-LIMB. Compared to the DMC plus hand, the i-LIMB was more reliable when holding objects but had a lack of power and was less robust. We concluded that the i-LIMB hand has limited additional functionality compared to the DMC plus hand.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Light, C. M., Chappell, P. H., & Kyberd, P. J. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2002.32737 · Cited by 417 · cited 1×
“A score of 98 of the Index of Functionality, ranging from 0–100, is appropriate for an unimpaired population.(4,5) The Assessment of Capacity for Myoelectric Control (ACMC 2.”
Background
Cited by
Linear and Nonlinear Regression Techniques for Simultaneous and Proportional Myoelectric Control
Hahne, J. M., Biebmann, F., Jiang, N., Rehbaum, H., Farina, D., Meinecke, F. C., Muller, K.-R., & Parra, L. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305520 · Cited by 365
Classification of Simultaneous Movements Using Surface EMG Pattern Recognition
Young, A. J., Smith, L. H., Rouse, E. J., & Hargrove, L. J. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2232293 · Cited by 320
Medical Robots: Current Systems and Research Directions
Beasley, R. A. (2012) · Journal of Robotics · doi:10.1155/2012/401613 · Cited by 312
Targeted Muscle Reinnervation and Advanced Prosthetic Arms
Cheesborough, J., Smith, L., Kuiken, T., & Dumanian, G. (2015) · Seminars in Plastic Surgery · doi:10.1055/s-0035-1544166 · Cited by 206
Modality-Specific Axonal Regeneration: Toward Selective Regenerative Neural Interfaces
Lotfi, P., Garde, K., Chouhan, A. K., Bengali, E., & Romero-Ortega, M. I. (2011) · Frontiers in Neuroengineering · doi:10.3389/fneng.2011.00011 · Cited by 42
“Advanced robotic prosthetic limbs designed with multiple degrees of freedom bear great promise as substitutes for the human arm/hand in amputees (Lin and Huang, 1997; Miller et al., 2008; Velliste et al., 2008; Matrone et al., 2010; Otr et al., 2010).”
BackgroundInfluential
Metadata
- Authors
- Van Der Niet, O., Reinders-Messelink, H. A., Bongers, R. M., Bouwsema, H., & Van Der Sluis, C. K.
- Venue
- Prosthetics & Orthotics International
- Published
- 2010-06
- Volume
- 34
- Issue
- 2
- Pages
- 216-220
- ISSN
- 0309-3646 (ISSN-L)
- OpenAlex
- W2161135398
- Cited by
- 87
- References
- 1
- FWCI
- 2.73
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The i-LIMB Hand and the DMC Plus Hand Compared: A Case Report. https://app.cochat.ai/papers/10.3109/03093641003767207
- The paper
- Van Der Niet, O., Reinders-Messelink, H. A., Bongers, R. M., Bouwsema, H., & Van Der Sluis, C. K. (2010). The i-LIMB Hand and the DMC Plus Hand Compared: A Case Report. Prosthetics & Orthotics International. https://doi.org/10.3109/03093641003767207
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.