Standardized in vitro drug release test for colloidal drug carriers using modified USP dissolution apparatus I
The DOI matches its Crossref record.
Abstract
BACKGROUND: Recently the use of colloidal carriers as drug delivery systems is gaining more attention. Evaluation of the in vitro drug release is considered an important step during the development and quality control of such systems. Therefore, there is a need for a standard test technique to study in vitro drug release from colloidal systems. METHODS: The glass basket dialysis method was performed by a modification to the USP dissolution apparatus I by replacing the baskets with glass cylinders closed at the lower end by dialysis membrane. This method was characterized for the essential test parameters and compared to the dialysis bags technique using different types of colloidal drug carriers, namely liposomes, polymeric, and lipid nanoparticles. RESULTS: The method proved to be more discriminating than the conventional dialysis bag method and allowed for better comparison between different formulation parameters or experimental conditions. In general, the design is easy to perform, simple, and available in all pharmaceutical laboratories under the same setup. CONCLUSION: The described method is a step toward standardized dissolution tests on colloidal drug delivery systems and the possible comparability of results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Analytical characterization of liposomes and other lipid nanoparticles for drug delivery
Fan, Y., Marioli, M., & Zhang, K. (2021) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2020.113642 · Cited by 395
Sustained-release from nanocarriers: a review
Natarajan, J. V., Nugraha, C., Ng, X. W., & Venkatraman, S. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.05.029 · Cited by 285
A Review of In Vitro Drug Release Test Methods for Nano-Sized Dosage Forms
D’Souza, S. (2014) · Advances in Pharmaceutics · doi:10.1155/2014/304757 · Cited by 262
“Figure 5: Comparison ofUSP I (left) and glass basket dialysis (right) set-ups (adapted from [27]).”
BackgroundMethodShen, J., & Burgess, D. J. (2013) · Drug Delivery and Translational Research · doi:10.1007/s13346-013-0129-z · Cited by 201
“The effect of particle size on the in vitro drug release profiles of the polymeric nanoparticles has also been demonstrated using this method [15].”
Nanocarriers for intravenous injection—The long hard road to the market
Wacker, M. (2013) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2013.08.079 · Cited by 170
Metadata
- Authors
- Abdel-Mottaleb, M. M. A., & Lamprecht, A.
- Venue
- Drug Development and Industrial Pharmacy
- Publisher
- Informa UK Limited
- Published
- 2010-08-12
- Volume
- 37
- Issue
- 2
- Pages
- 178-184
- ISSN
- 0363-9045 (ISSN-L)
- 1520-5762
- OpenAlex
- W2150900483
- Cited by
- 79
- References
- 0
- FWCI
- 2.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Standardized in vitro drug release test for colloidal drug carriers using modified USP dissolution apparatus I. https://app.cochat.ai/papers/10.3109/03639045.2010.502534
- The paper
- Abdel-Mottaleb, M. M. A., & Lamprecht, A. (2011). Standardized in vitro drug release test for colloidal drug carriers using modified USP dissolution apparatus I. Drug Development and Industrial Pharmacy. https://doi.org/10.3109/03639045.2010.502534
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.