CoChat

In Vivo Strain Analysis of the Greyhound Femoral Diaphysis

Szivek, J. A., Johnson, E. M., Magee, F. P. · 1992 · Journal of Investigative Surgery
Cited by 51

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Subminiature single element and rosette strain gauges used for deformation measurement were prepared for surgical implantation using a technique published previously (Szivek JA, Magee FP. J Invest Surg. 1989;2:195-206). During surgery, gauges were placed on the anterior, lateral, and medial aspects of the mid-diaphysis of one femur in six greyhounds. Motion and gait analyses were performed to ensure uniform weight bearing prior to strain monitoring. In vivo strain measurements were obtained during normal gait at several speeds on a treadmill. After a 3-month holding period, strain gauges that were implanted on the contralateral femur were monitored. All animals were euthanized and both their femora explanted. Following embedding and histological preparation of the explanted femora, strain measurements were plotted on diagrams of the section shapes of the mid-diaphysis of each femur. Strain distribution diagrams indicated that peak strain levels and strain distributions changed during different phases of gait. Increases in gait speed increased the peak strain levels. In addition, the anterior rather than anterior-lateral aspect of the femur exhibited the highest strain during midstance. Measurements taken from rosette gauges indicated that the principal compressive strain direction was oriented slightly off axis to the long axis of the femur. Measurements from gauges placed along the length of the femur indicated an average strain change of 22.3 microstrain +/- 12.2% over a 2-cm length in the mid-diaphysis. These measurements provide a baseline describing the strain state of the greyhound femur and can be used in computer modeling.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3109/08941939209012426

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 51

Metadata

Authors
Szivek, J. A., Johnson, E. M., & Magee, F. P.
Venue
Journal of Investigative Surgery
Published
1992-01
Volume
5
Issue
2
Pages
91-108
ISSN
  • 0894-1939 (ISSN-L)
  • 1521-0553
OpenAlex
W2072403469
Cited by
51
References
2
FWCI
4.95
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: In Vivo Strain Analysis of the Greyhound Femoral Diaphysis. https://app.cochat.ai/papers/10.3109/08941939209012426
The paper
Szivek, J. A., Johnson, E. M., & Magee, F. P. (1992). In Vivo Strain Analysis of the Greyhound Femoral Diaphysis. Journal of Investigative Surgery. https://doi.org/10.3109/08941939209012426

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.