CoChat

Development and characterization of a Versatile Engineered Nanomaterial Generation System (VENGES) suitable for toxicological studies

Open access
Demokritou, Philip, Büchel, Robert, Molina, Ramon M., Deloid, Glen M., Brain, Joseph D., Pratsinis, Sotiris E. · 2010 · Inhalation Toxicology
Cited by 60

The DOI matches its Crossref record.

Abstract

Philip Demokritou*a, Robert Büchelb, Ramon M. Molinac, Glen M. Deloidc, Joseph D. Brainc & Sotiris E. Pratsinisba Exposure Epidemiology and Risk Program, Department of Environmental Health, Harvard School of Public Health, Boston, MA, USAb Particle Technology Laboratory, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerlandc Molecular and Integrative Physiological Sciences, Department of Environmental Health, Harvard School of Public Health, Boston, MA, USAAddress for Correspondence: Philip Demokritou, PhD, Department of Environmental Health, School of Public Health, Harvard University, 401 Park Drive, BOX 15677. Landmark Center—West, Boston, MA 02215, USA; Tel: (617) 3848847; E-mail: pdemokri@hsph.harvard.eduA novel system for generation of engineered nanomaterials (ENMs) suitable for in situ toxicological characterization within biological matrices was developed. This Versatile Engineered Nanomaterial Generation System (VENGES) is based on industry-relevant, flame spray pyrolysis aerosol reactors that can scaleably produce ENMs with controlled primary and aggregate particle size, crystallinity, and morphology. ENMs are produced continuously in the gas phase, allowing their continuous transfer to inhalation chambers, without altering their state of agglomeration. Freshly generated ENMs are also collected on Teflon filters for subsequent physicochemical and morphological characterization and for in vitro toxicological studies. The ability of the VENGES system to generate families of ENMs of pure and selected mixtures of iron oxide, silica, and nanosilver with controlled physicochemical properties was demonstrated using a range of state-of-the-art-techniques. Specific surface area was measured by nitrogen adsorption using the Brunauer–Emmett–Teller method, and crystallinity was characterized by X-ray diffraction. Particle morphology and size were evaluated by scanning and transmission electron microscopy. The suitability of the VENGES system for toxicological studies was also shown in both in vivo and in vitro studies involving Sprague–Dawley rats and human alveolar-like monocyte derived macrophages, respectively. We demonstrated linkage between physicochemical ENM properties and potential toxicity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3109/08958378.2010.499385

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 60

Metadata

Authors
Demokritou, P., Büchel, R., Molina, R. M., Deloid, G. M., Brain, J. D., & Pratsinis, S. E.
Venue
Inhalation Toxicology
Published
2010-08-11
Volume
22
Issue
sup2
Pages
107-116
ISSN
  • 0895-8378 (ISSN-L)
  • 1091-7691
OpenAlex
W2152648144
Cited by
60
References
0
FWCI
1.85
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Development and characterization of a Versatile Engineered Nanomaterial Generation System (VENGES) suitable for toxicological studies. https://app.cochat.ai/papers/10.3109/08958378.2010.499385
The paper
Demokritou, P., Büchel, R., Molina, R. M., Deloid, G. M., Brain, J. D., & Pratsinis, S. E. (2010). Development and characterization of a Versatile Engineered Nanomaterial Generation System (VENGES) suitable for toxicological studies. Inhalation Toxicology. https://doi.org/10.3109/08958378.2010.499385

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.