A Simple Methylene Blue-Azure Ii-Basic Fuchsin Stain for Epoxy-Embedded Tissue Sections
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
One micron-thick sections of tissues fixed in glutaraldehyde, or in glutaraldehyde followed by osmium tetroxide, and embedded in a variety of plastic resins were stained in a methylene blue-azure II solution at 65 C, then counterstained in 0.05% basic fuchsin in 2.5% ethanol at room temperature (24 C). Considerable variation was found in methylene blue-azure II staining times for different embedding media. Aged Epon-812 required less staining time than freshly polymerized blocks of Epon-812. The procedure is a simple, rapid staining technique suitable for photomicrography and tissue orientation for electron microscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A low-viscosity epoxy resin embedding medium for electron microscopy
Spurr, A. R. (1969) · Journal of Ultrastructure Research · doi:10.1016/s0022-5320(69)90033-1 · Cited by 12,865
IMPROVEMENTS IN EPOXY RESIN EMBEDDING METHODS
Luft, J. H. (1961) · The Journal of Cell Biology · doi:10.1083/jcb.9.2.409 · Cited by 10,212
Embedding in Epoxy Resins for Ultrathin Sectioning in Electron Microscopy
Richardson, K. C., Jarett, L., & Finke, E. H. (1960) · Stain Technology · doi:10.3109/10520296009114754 · Cited by 3,295
PLASTIC EMBEDDING MIXTURES FOR USE IN ELECTRON MICROSCOPY.
Mollenhauer, H. H. (1964) · PubMed · Cited by 1,972
A method for staining epoxy sections for light microscopy
Trump, B. F., Smuckler, E. A., & Benditt, E. P. (1961) · Journal of Ultrastructure Research · doi:10.1016/s0022-5320(61)80011-7 · Cited by 861
Histological Techniques for Electron Microscopy
Myrvik, Q. N., & Pease, D. C. (1961) · AIBS Bulletin · doi:10.2307/1292618 · Cited by 831
A NEW MARAGLAS, D.E.R.® 732, EMBEDMENT FOR ELECTRON MICROSCOPY
Erlandson, R. A. (1964) · The Journal of Cell Biology · doi:10.1083/jcb.22.3.704 · Cited by 232
A Basic Fuchsin and Alkalinized Methylene Blue Rapid Stain for Epoxyembedded Tissue
Huber, J. D., Parker, F., & Odland, G. F. (1968) · Stain Technology · doi:10.3109/10520296809115048 · Cited by 182
Aparicio, S. R., & Marsden, P. (1969) · Journal of Microscopy · doi:10.1111/j.1365-2818.1969.tb00659.x · Cited by 91
Basic Two-Dye Stains for Epoxy-Embedded 0.3-1 μ Sections
Sievers, J. (1971) · Stain Technology · doi:10.3109/10520297109067853 · Cited by 75
Removal of epoxy resin from histological sections following halogenation.
Yensen, J. (1968) · PubMed · Cited by 41
Cited by
Kramer-Zucker, A. G., Olale, F., Haycraft, C. J., Yoder, B. K., Schier, A. F., & Drummond, I. A. (2005) · Development · doi:10.1242/dev.01772 · Cited by 669
Identification of separate slow and fast muscle precursor cells in vivo, prior to somite formation
Devoto, S. H., Melançon, E., Eisen, J. S., & Westerfield, M. (1996) · Development · doi:10.1242/dev.122.11.3371 · Cited by 666
Cell movements during epiboly and gastrulation in zebrafish
Warga, R. M., & Kimmel, C. B. (1990) · Development · doi:10.1242/dev.108.4.569 · Cited by 563
Induction of muscle pioneers and floor plate is distinguished by the zebrafish no tail mutation
Halpern, M. (1993) · Cell · doi:10.1016/0092-8674(93)90682-g · Cited by 508
Drummond, I. A., Majumdar, A., Hentschel, H., Elger, M., Solnica-Krezel, L., Schier, A. F., Neuhauss, S. C. F., Stemple, D. L., Zwartkruis, F., Rangini, Z., et al. (1998) · Development · doi:10.1242/dev.125.23.4655 · Cited by 486
Metadata
- Authors
- Humphrey, C. D., & Pittman, F. E.
- Venue
- Stain Technology
- Publisher
- Informa UK Limited
- Published
- 1974-01
- Volume
- 49
- Issue
- 1
- Pages
- 9-14
- ISSN
- 0038-9153 (ISSN-L)
- OpenAlex
- W2221233133
- Cited by
- 505
- References
- 11
- FWCI
- 5.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.