Enhanced Brain Tumor Selectivity of Cationic Magnetic Polysaccharide Microspheres
The DOI matches its Crossref record.
Abstract
A novel cationic delivery system composed of magnetic aminodextran microspheres (MADM) 1-2 microm in diameter was evaluated along with neutral magnetic dextran microspheres (MDM) for their ability to target intracerebral rat glioma-2 (RG-2) tumors in vivo. The tissue distribution of the microspheres was determined following intraarterial injection (25 mg/kg) over 2 min in male Fisher 344 rats bearing RG-2 tumors as well as normal animals with a magnetic field of 0 or 0.6 T applied to the brain for 30 min. Animals were sacrificed at 30 min or 6 h post-injection after which the microspheres were recovered from various tissues and analyzed for magnetite (Fe3O4) content by atomic absorption. Overall, administration of cationic MADM and neutral MDM particles in normal animals resulted in low brain tissue concentrations with the highest concentrations observed in lung and spleen tissue. In contrast, studies in brain tumor bearing animals resulted in cationic MADM particles concentrating in brain tumor at levels significantly higher than neutral MDM particles (p = 0.0111). Cationic particles were also retained in brain tissue over a longer period of time compared to neutral particles (p = 0.0161) with MADM tumor concentrations decreasing only 4% after 6h compared with a 32% decrease for MDM. Application of a magnetic field failed to produce any significant effect on tissue distribution due to high variability in these groups, but generally resulted in increased brain concentrations and decreased non-target tissue concentrations. TEM analysis of brain tissue sections in tumor animals also revealed differences in particle distribution with MADM particles observed in the interstitial space and MDM particles trapped in the vasculature. In summary, particle charge, state of the vascular endothelium and time significantly influenced particle distribution contributing to the ability of MADM to selectively target brain tumor and supports further investigation of magnetic cationic microspheres as a targeted drug delivery system for brain tumors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Applications of magnetic nanoparticles in biomedicine
Pankhurst, Q. A., Connolly, J., Jones, S. K., & Dobson, J. (2003) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/36/13/201 · Cited by 5,881
Applications of Magnetic Nanoparticles in Biomedicine
Bárcena, C., Sra, A. K., & Gao, J. (2009) · Nanoscale Magnetic Materials and Applications · doi:10.1007/978-0-387-85600-1_20 · Cited by 2,565
Mahmoudi, M., Sant, S., Wang, B., Laurent, S., & Sen, T. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2010.05.006 · Cited by 1,881
Nanoparticulate systems for brain delivery of drugs.
Kreuter, J. (2001) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(00)00122-8 · Cited by 1,107
Superparamagnetic Colloids: Controlled Synthesis and Niche Applications
Jeong, U., Teng, X., Wang, Y., Yang, H., & Xia, Y. (2007) · Advanced Materials · doi:10.1002/adma.200600674 · Cited by 982
Metadata
- Authors
- Pulfer, S. K., & Gallo, J. M.
- Venue
- Journal of Drug Targeting
- Publisher
- Informa UK Limited
- Published
- 1998-01
- Volume
- 6
- Issue
- 3
- Pages
- 215-227
- ISSN
- 1026-7158 (ISSN-L)
- 1061-186X
- 1029-2330
- OpenAlex
- W2159111659
- Cited by
- 69
- References
- 0
- FWCI
- 1.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Enhanced Brain Tumor Selectivity of Cationic Magnetic Polysaccharide Microspheres. https://app.cochat.ai/papers/10.3109/10611869808997896
- The paper
- Pulfer, S. K., & Gallo, J. M. (1998). Enhanced Brain Tumor Selectivity of Cationic Magnetic Polysaccharide Microspheres. Journal of Drug Targeting. https://doi.org/10.3109/10611869808997896
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.