Medication Dosing Errors in Pediatric Patients Treated by Emergency Medical Services
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Medication dosing errors occur in up to 17.8% of hospitalized children. There are limited data to describe pediatric medication errors by emergency medical services (EMS) paramedics. It has been shown that paramedics have infrequent encounters with pediatric patients. OBJECTIVE: To characterize medication dosing errors in children treated by EMS. METHODS: We studied patients aged ≤11 years who were treated by paramedics from eight Michigan EMS agencies from January 2004 through March 2006. We defined a medication dosing error as ≥20% deviation from the weight-appropriate dose, as determined by the patient's reported weight in the prehospital medical record or by use of the Broselow-Luten tape (BLT). We studied errors in administering six EMS medications commonly given to children: albuterol, atropine, dextrose, diphenhydramine, epinephrine, and naloxone. RESULTS: There were 5,547 children aged ≤11 years who were treated during the study period, of whom 230 (4.1%) received drugs and had a documented weight. These patients received a total of 360 medication administrations. Multiple drug administrations occurred in 73 cases. Medication dosing errors occurred in 125 of the 360 drug administrations (34.7%; 95% confidence interval [CI] 30.0, 39.8). Relative drug dosage errors (with 95% CI) were as follows: albuterol 23.3% (18.4, 29.1), atropine 48.8% (34.3, 63.5), diphenhydramine 53.8% (29.1, 76.8), and epinephrine 60.9% (49.9, 73.9). The mean error (± standard deviation) for intravenous/intraosseous 1:1000 epinephrine overdoses was 808% ± 428%. The mean error (± standard deviation) for intravenous/intraosseous 1:1000 epinephrine underdoses was 35.5% ± 27.4%. CONCLUSIONS: Medications delivered in the prehospital care of children were frequently administered outside of the proper dose range when compared with patient weights recorded in the prehospital medical record. EMS systems should develop strategies to reduce pediatric medication dosing errors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Medication Errors and Adverse Drug Events in Pediatric Inpatients
Kaushal, R. (2001) · JAMA · doi:10.1001/jama.285.16.2114 · Cited by 1,917
Cited by
Barriers and Facilitators to Pediatric Emergency Telemedicine in the United States
Uscher-Pines, L., & Kahn, J. M. (2014) · Telemedicine and e-Health · doi:10.1089/tmj.2014.0015 · Cited by 81
Metadata
- Authors
- Hoyle, J. D., Davis, A. T., Putman, K. K., Trytko, J. A., & Fales, W. D.
- Venue
- Prehospital Emergency Care
- Publisher
- Informa UK Limited
- Published
- 2012-01
- Volume
- 16
- Issue
- 1
- Pages
- 59-66
- ISSN
- 1090-3127 (ISSN-L)
- 1545-0066
- OpenAlex
- W2078546971
- Cited by
- 171
- References
- 1
- FWCI
- 11.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.