Chronic Inhalation Study Findings as a Basis for Proposing a New Occupational Dust Exposure Limit
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This article briefly reviews the history of the current threshold limit value and the permissible exposure limit for occupational dusts derived originally from the Nuisance Dust standard. Chronic inhalation studies of appropriate design are described in terms of their key findings and potential impact on the dust standards, especially modern, experimental studies which have been affected by the problem of dust overloading. Many studies show that dust overloading produces a significant and progressive retardation of macrophage-mediated dust removal leading to various dysfunctional and pathologic changes which confound the interpretation of chronic toxicity study findings. Assuming that there may be a human counterpart to this condition at the same milligram dust per gram lung concentration, extrapolation modeling can be used to show that the current occupational dust limits do not protect worker lungs from this eventuality. Several bases for substantially reducing the current occupational standards are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Possible mechanisms to explain dust overloading of the lungs
MORROW, P. (1988) · Fundamental and Applied Toxicology · doi:10.1016/0272-0590(88)90284-9 · Cited by 500
Self-citationLung Clearance of Inhaled Insoluble and Soluble Particles
OBERDÖRSTER, G. (1988) · Journal of Aerosol Medicine · doi:10.1089/jam.1988.1.289 · Cited by 157
Cited by
Airborne Nanostructured Particles and Occupational Health
Maynard, A. D., & Kuempel, E. D. (2005) · Journal of Nanoparticle Research · doi:10.1007/s11051-005-6770-9 · Cited by 559
Heinrich, U., Fuhst, R., Rittinghausen, S., Creutzenberg, O., Bellmann, B., Koch, W., & Levsen, K. (1995) · Inhalation Toxicology · doi:10.3109/08958379509015211 · Cited by 514
TOXICOKINETICS AND EFFECTS OF FIBROUS AND NONFIBROUS PARTICLES
Oberdörster, G. (2002) · Inhalation Toxicology · doi:10.1080/089583701753338622 · Cited by 221
Dust overloading of the lungs: Update and appraisal
Morrow, P. E. (1992) · Toxicology and Applied Pharmacology · doi:10.1016/0041-008x(92)90002-a · Cited by 198
Self-citationWarheit, D. B., Hansen, J. F., Yuen, I. S., Kelly, D. P., Snajdr, S. I., & Hartsky, M. A. (1997) · Toxicology and Applied Pharmacology · doi:10.1006/taap.1997.8102 · Cited by 165
Metadata
- Authors
- Morrow, P. E., Muhle, H., & Mermelstein, R.
- Venue
- Journal of the American College of Toxicology
- Publisher
- SAGE Publications
- Published
- 1991-03
- Volume
- 10
- Issue
- 2
- Pages
- 279-290
- ISSN
- 0730-0913 (ISSN-L)
- OpenAlex
- W2119816698
- Cited by
- 65
- References
- 2
- FWCI
- 4.56
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Chronic Inhalation Study Findings as a Basis for Proposing a New Occupational Dust Exposure Limit. https://app.cochat.ai/papers/10.3109/10915819109078637
- The paper
- Morrow, P. E., Muhle, H., & Mermelstein, R. (1991). Chronic Inhalation Study Findings as a Basis for Proposing a New Occupational Dust Exposure Limit. Journal of the American College of Toxicology. https://doi.org/10.3109/10915819109078637
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.