The DOI matches its Crossref record.
A JAVA environment for medical image data analysis: Initial application for brain PET quantitation
Abstract
Analysis software for medical image data tends to be expensive and usable only in a restricted environment. Therefore the aim of the current project was to implement a flexible framework for medical image processing and visualization which is portable among platforms and open to different data formats including DICOM 3.0. The software was designed as a set of tools which encapsulate specialized functionality. The tools are full stand alone applications, but they are also able to present a co-operating environment within which images and other information are communicated in real time. Currently, the emphasis is on quantitative analysis of PET data by kinetic modelling. However, general viewing capabilities are included, and the design is flexible enough that other types of processing can easily be integrated by simply plugging in Java classes. The software is successfully applied to PET data quantitation in clinical research studies and even patient studies. Portability was aimed at by encoding the programs in Java. Experience shows that the implementation of such a complex and computationally demanding Java application is feasible. Although there are major portability issues to consider, configurations can be found on which the software runs stably and at a speed comparable to C code if just-in-time compilation is available.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ichise, M., Liow, J.-S., Lu, J.-Q., Takano, A., Model, K., Toyama, H., Suhara, T., Suzuki, K., Innis, R. B., & Carson, R. E. (2003) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/01.wcb.0000085441.37552.ca · Cited by 650
In Vivo Evidence for Lactate as a Neuronal Energy Source
Wyss, M. T., Jolivet, R., Buck, A., Magistretti, P. J., & Weber, B. (2011) · The Journal of Neuroscience · doi:10.1523/jneurosci.0415-11.2011 · Cited by 437
Burger, C., Goerres, G., Schoenes, S., Buck, A., Lonn, A., & von Schulthess, G. (2002) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-002-0796-3 · Cited by 428
Self-citationDe Quervain, D. J. ‐., Henke, K., Aerni, A., Treyer, V., McGaugh, J. L., Berthold, T., Nitsch, R. M., Buck, A., Roozendaal, B., & Hock, C. (2003) · European Journal of Neuroscience · doi:10.1046/j.1460-9568.2003.02542.x · Cited by 342
Huber, R., Treyer, V., Borbély, A. A., Schuderer, J., Gottselig, J. M., Landolt, H. ‐., Werth, E., Berthold, T., Kuster, N., Buck, A., et al. (2002) · Journal of Sleep Research · doi:10.1046/j.1365-2869.2002.00314.x · Cited by 332
Metadata
- Authors
- Mikolajczyk, K., Szabatin, M., Rudnicki, P., Grodzki, M., & Burger, C.
- Venue
- Medical Informatics
- Publisher
- Informa UK Limited
- Published
- 1998-01
- Volume
- 23
- Issue
- 3
- Pages
- 207-214
- ISSN
- 0307-7640 (ISSN-L)
- OpenAlex
- W2000029267
- Cited by
- 179
- References
- 0
- FWCI
- 5.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A JAVA environment for medical image data analysis: Initial application for brain PET quantitation. https://app.cochat.ai/papers/10.3109/14639239809001400
- The paper
- Mikolajczyk, K., Szabatin, M., Rudnicki, P., Grodzki, M., & Burger, C. (1998). A JAVA environment for medical image data analysis: Initial application for brain PET quantitation. Medical Informatics. https://doi.org/10.3109/14639239809001400
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.