Noninvasive evaluation of splanchnic tissue oxygenation using near-infrared spectroscopy in preterm neonates
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Diagnosis of necrotizing enterocolitis (NEC) in preterm neonates is challenging. We hypothesized that regional splanchnic oxygen saturation (rsSO₂) measured by near-infrared spectroscopy (NIRS) is a biomarker for mesenteric perfusion. OBJECTIVE: To evaluate feasibility and safety of continuous rsSO₂ monitoring in preterm infants in the first 14 days of life. METHODS: Preterm neonates ≤30 weeks' gestation had a NIRS sensor placed in the left paraumbilical region within 48 h of birth. rsSO₂ was recorded every 30 s. Clinical data including pulse oximetry (SaO₂) were recorded. Fractional tissue oxygen extraction (FTOE) was computed as follows: (SaO₂ - rsSO₂) × 100/SaO₂. RESULTS: Of 21 infants enrolled, 2 were excluded because of skin breakdown and missing data. Daily mean rsSO₂ values decreased over the first 9 days (p < 0.0001) followed by an increase from day 10 (D10) to D14 (p = 0.0061). rsSO(2) was lower and FTOE was higher in infants with feeding intolerance compared to those without feeding intolerance (p = 0.0043). rsSO₂ accounted for ≥99.5% of the variance in FTOE. Two neonates with NEC had persistently low rsSO₂ with loss of variability preceded or followed by very high rsSO₂. CONCLUSIONS: We have reported feasibility, safety and ranges for rsSO₂ for a small number of preterm infants in the first 2 weeks of life.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Phases of Biomarker Development for Early Detection of Cancer
Pepe, M. S., Etzioni, R., Feng, Z., Potter, J. D., Thompson, M. L., Thornquist, M., Winget, M., & Yasui, Y. (2001) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/93.14.1054 · Cited by 1,686 · cited 2×
“Since Phase I Exploratory studies for biomarker development are hypothesis-generating and not hypothesis-testing, formal sample size calculations based on statistical tests of hypotheses were not necessary [7].”
BackgroundMethodSmall studies: strengths and limitations
Hackshaw, A. (2008) · European Respiratory Journal · doi:10.1183/09031936.00136408 · Cited by 496 · cited 1×
“Such studies are often performed in a small number of subjects initially [26].”
Background
Metadata
- Authors
- Cortez, J., Gupta, M., Amaram, A., Pizzino, J., Sawhney, M., & Sood, B. G.
- Venue
- The Journal of Maternal-Fetal & Neonatal Medicine
- Publisher
- Informa UK Limited
- Published
- 2010-09-09
- Volume
- 24
- Issue
- 4
- Pages
- 574-582
- ISSN
- 1476-4954 (ISSN-L)
- 1476-7058
- OpenAlex
- W2041472440
- Cited by
- 163
- References
- 3
- FWCI
- 6.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noninvasive evaluation of splanchnic tissue oxygenation using near-infrared spectroscopy in preterm neonates. https://app.cochat.ai/papers/10.3109/14767058.2010.511335
- The paper
- Cortez, J., Gupta, M., Amaram, A., Pizzino, J., Sawhney, M., & Sood, B. G. (2011). Noninvasive evaluation of splanchnic tissue oxygenation using near-infrared spectroscopy in preterm neonates. The Journal of Maternal-Fetal & Neonatal Medicine. https://doi.org/10.3109/14767058.2010.511335
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.