Smartphone hearing screening with integrated quality control and data management

Swanepoel, De Wet, Myburgh, Hermanus C., Howe, David M., Mahomed, Faheema, Eikelboom, Robert H. · 2014 · International Journal of Audiology
Cited by 158

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

De Wet Swanepoel*abcd, Hermanus C. Myburghe, David M. Howeae, Faheema Mahomeda & Robert H. Eikelboomabca *Department of Speech-Language Pathology and Audiology, University of Pretoria, Pretoria, South Africab Ear Sciences Centre, School of Surgery, The University of Western Australia, Nedlands, Australiac Ear Science Institute Australia, Subiaco, Australiad Callier Center for Communication Disorders, University of Texas at Dallas, USAe Department of Electrical, Electronic and Computer Engineering, University of Pretoria, Pretoria, South AfricaCorrespondence: De Wet Swanepoel, Department of Speech-Language Pathology and Audiology, University of Pretoria, Pretoria, 0002, South Africa. E-mail: dewet.swanepoel@up.ac.zaAbstractObjective: To determine if a smartphone application could be used as a calibrated screening audiometer with real-time noise monitoring for school screening using automated test sequences. Design: The investigation comprised three studies. Study 1 evaluated calibration accuracy across four Samsung S5301 smartphones (Android v4.0.4) using commercial Sennheiser HD202 headphones. Study 2 involved referencing smartphone microphone sensitivity to narrowband noise intensity as measured in octave bands by a sound-level meter between 30 and 75 dB SPL (5 dB increments). Study 3 compared screening outcomes of smartphone based and conventional hearing screening. Study sample: Study 2: 15 normal-hearing subjects (age range, 18–22 years; all female). Study 3: 162 children (324 ears) aged 5 to 7 years. Results: Smartphone calibration at 20, 30, and 40 dB was within 1 dB of recommended reference equivalent thresholds levels. Microphone calibration for noise monitoring had maximum variability across phones of 0.9, 0.6, and 2.9 dB at 1, 2, and 4 kHz, respectively, from reference intensities (30 to 75 dB SPL). Screening outcomes demonstrated no significant difference between smartphone and conventional audiometry with an overall referral rate of 4.3% and 3.7%, respectively. Conclusions: The newly developed smartphone application can be accurately calibrated for audiometry with valid real-time noise monitoring, and clinical results are comparable to conventional screening.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3109/14992027.2014.920965

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 158

Metadata

Authors
Swanepoel, D. W., Myburgh, H. C., Howe, D. M., Mahomed, F., & Eikelboom, R. H.
Venue
International Journal of Audiology
Published
2014-07-07
Volume
53
Issue
12
Pages
841-849
ISSN
  • 1499-2027 (ISSN-L)
  • 1708-8186
OpenAlex
W2021010502
Cited by
158
References
1
FWCI
5.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Smartphone hearing screening with integrated quality control and data management. https://app.cochat.ai/papers/10.3109/14992027.2014.920965
The paper
Swanepoel, D. W., Myburgh, H. C., Howe, D. M., Mahomed, F., & Eikelboom, R. H. (2014). Smartphone hearing screening with integrated quality control and data management. International Journal of Audiology. https://doi.org/10.3109/14992027.2014.920965

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.