Cited by 22Electromagnetic Fields and Biological EffectsMagnetic and Electromagnetic EffectsBiofield Effects and Biophysics

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Power-Dependent Rearrangement in the Spectrum of Resonance Effect of Millimeter Waves on the Genome Conformational State of Escherichia Coli Cells

Shcheglov, Victor S., Ya. Belyaev, Igor, Alipov, Yevgeny D., Ushakov, Vadim L.·1997·Electro- and Magnetobiology

Abstract

The Escherichia coli cells K12 AB1157 from the stationary stage of growth were exposed to millimeter waves (MMW) at power densities (PD) from 10−8 W/cm2 to 3 × 10−3 W/cm2. Frequency dependencies during exposure within the range of 51.655–51.688 GHz were studied for two cell concentrations (4 × 107 and 4 × 108 cells/ml). The changes in the genome conformational state (GCS) were analyzed by the method of anomalous viscosity time dependence (AVTD). The resonant effect with the resonance frequency of 51.675 ± 0.001 GHz was observed in the PD range of 10−18-10−8 W/cm2. Left-handed polarized MMW was shown to be more effective than right-handed circular polarization at this resonance. At PDs more than 10−6 W/cm2 the 51.675 GHz resonance effect decreased significantly. As the 51.675 GHz resonance decreased, a statistically significant effect was observed with its maximum at 51.668 ± 0.002 GHz. The results were compared to data of previous studies performed at the resonance frequency of 51.755 GHz. All resonance effects depended on the concentration of cells during exposure, which implies a cell-to-cell interaction during resonance response (cooperativity of resonance response). At all resonance frequencies, an effect was observed at very low nonthermal intensities: 10−18 W/cm2 for 51.755 GHz and 51.675 GHz; 10−14 W/cm2 for 51.668 GHz. The values of three resonance frequencies were stable in wide PD ranges within 10−18-10−3 W/cm2. The half-widths of the resonances showed different dependencies on PD, changing from 2–3 MHz to 16–17 MHz (51.675 GHz, 51.668 GHz) or 100 MHz (51.755 GHz). The significant rearrangement in the spectrum of resonance response was observed in the 10−8-10−4 W/cm2. All three resonances were involved in this rearrangement which can be explained in the framework of the model of electron-conformational interactions.

Overview

Integrity signals

Registry

Crossref · 10.3109/15368379709016174

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Most of the Belyaev research group experiments on the resonance effect of MMWs changing the conformation state of chromosomal DNA complexes were not temperature controlled.

    “The Belyaev research group reported that the resonance effect of MMWs can change the conformation state of chromosomal DNA complexes [64–74]; however, most of these experiments were not temperature controlled.”

Citations

Cites

Flagged first, then by citations

Research works printed but not linked: 25

  1. 10.1126/science.174.4004.72 · DOI
  2. Vilenskaya R. L., 1972, Bull. Eksperim. Biol. Med., 4, 52
  3. 10.3367/UFNr.0110.197307l.0453 · DOI
  4. 10.1007/978-3-642-73309-3_4 · DOI
  5. Belyaev I. Ya., 1992, Z. Natur‐forsch., 47, 621
  6. Belyaev I. Ya., 1994, Z. Naturforsch., 49, 352, 10.1515/znc-1994-5-612 · DOI · Paper page
  7. 10.1007/978-1-4615-9837-4_10 · DOI · Paper page
  8. 10.1016/0302-4598(92)87015-M · DOI · Paper page
  9. 10.3109/15368379209009820 · DOI · Paper page
  10. 10.3109/15368379309012861 · DOI · Paper page
  11. 10.1016/0302-4598(93)86105-A · DOI · Paper page
  12. 10.3109/15368379409030698 · DOI · Paper page
  13. 10.1007/978-3-642-69186-7_6 · DOI
  14. Gandhi O. P, 1983, J. Microw. Power, 18, 295, 10.1080/16070658.1983.11689334 · DOI
  15. 10.1016/0302-4598(92)87010-R · DOI
  16. 10.1002/(SICI)1521-186X(1996)17:4<312::AID-BEM7>3.0.CO;2-6 · DOI
  17. Belyaev I. Ya., 1994, Charge and Field Effects in Biosystems‐4, 174
  18. Didenko N. P., 1983, Effects of Nonthemzal Millimeter Waves on Biological Objects, 63
  19. Sitko S. P., 1984, Dokl. Acad. Nauk. USSR, 6, 63
  20. Keilmann F, 1986, Z. Naturforsch., 41, 795, 10.1515/znc-1986-7-821 · DOI
  21. Chernavskaya N. M., 1977, Tunnel Effect of Electrons in Photosynthesis
  22. Krawiec S., 1990, Microbiol. Rev., 54, 502, 10.1128/MMBR.54.4.502-539.1990 · DOI
  23. Kittel C, 1978, Introduction to Solid State Physics
  24. 10.1016/0302-4598(94)01763-Q · DOI
  25. Belyaev I. Ya., 1977, Bioelectromagnetics

Cited by

Sorted by citations

Metadata

Authors
Shcheglov, V. S., Ya. Belyaev, I., Alipov, Y. D., & Ushakov, V. L.
Affiliations
Institute of Engineering Physics (RU)
Venue
Electro- and Magnetobiology
Published
1997-01
Volume
16
Issue
1
Pages
69-82
ISSN
1061-9526 (ISSN-L)
OpenAlex
W1976291016
Cited by
22
References
1
Citations by year
2026: 1 · 2021: 2 · 2018: 1 · 2015: 1 · 2012: 1
FWCI
1.73
Type
journal article
Language
en
Open access
closed
Locations
Electro- and Magnetobiology (publishedVersion)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Electromagnetic Fields and Biological Effects
  • Life Sciences › Agricultural and Biological Sciences › Agronomy and Crop Science › Magnetic and Electromagnetic Effects
  • Health Sciences › Medicine › Complementary and alternative medicine › Biofield Effects and Biophysics
Keywords
millimeter wave, Escherichia coli, resonance effects, power density dependence, circular polarization, cell-cell interactions, non-thermal effects, stationary phase cells, resonant frequency shift, cell concentration dependence

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review