Respiratory Tract Inflammation in Swine Confinement Workers Studied Using Induced Sputum and Exhaled Nitric Oxide
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To further define the asthma-like syndrome seen in swine confinement workers. DESIGN: A cross-sectional study was performed at a swine confinement facility in rural Nebraska and at the University of Nebraska Medical Center, Omaha, Nebraska. PARTICIPANTS: 24 swine confinement workers and 14 urban normal control subjects. All subjects completed a questionnaire concerning respiratory complaints. We performed hypertonic saline challenges on the swine confinement workers and control subjects in order to induce expectoration of sputum. Cell counts and cell differentials were determined in the induced sputum samples. Nasal, mean, and peak exhaled nitric oxide was measured in both groups. Spirometry was also done. RESULTS: Swine confinement workers were significantly more likely to report wheezing, cough, and sinusitis symptoms than controls (p = .003). Macrophages were significantly elevated in the induced sputum samples of the swine confinement workers vs the control subjects (0.59 macrophages/mL +/- 0.1 SEM vs 0.36 +/- .16; p = .006), while there was no difference in numbers of neutrophils. No eosinophils were observed. A small elevation in mean exhaled nitric oxide was seen in the swine confinement workers compared to normal controls (11.7 ppb +/- 0.6 SEM vs 10.2 +/- 1.6; p = 0.023). Spirometry values did not differ statistically between swine confinement workers and the control group. CONCLUSIONS: Swine confinement workers have signs and symptoms of lower respiratory tract inflammation when studied using induced sputum and exhaled nitric oxide. Findings in the swine confinement workers differ from those in asthmatics and chronic bronchitis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Changes in the normal maximal expiratory flow-volume curve with growth and aging.
Knudson, R. J., Lebowitz, M. D., Holberg, C. J., & Burrows, B. A. (1983) · PubMed · doi:10.1164/arrd.1983.127.6.725 · Cited by 1,907
Cited by
Exhaled Markers of Pulmonary Disease
KHARITONOV, S. A., & BARNES, P. J. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.7.2009041 · Cited by 844
Biomarkers of some pulmonary diseases in exhaled breath
Kharitonov, S. A., & Barnes, P. J. (2002) · Biomarkers · doi:10.1080/13547500110104233 · Cited by 290
Intensive livestock operations, health, and quality of life among eastern North Carolina residents.
Wing, S., & Wolf, S. (2000) · Environmental Health Perspectives · doi:10.1289/ehp.00108233 · Cited by 271
Exhaled markers of inflammatory lung diseases: ready for routine monitoring?
Kharitonov, S. (2004) · Swiss Medical Weekly · doi:10.4414/smw.2004.10411 · Cited by 74
Exercise alters serum pneumoprotein concentrations
Nanson, C. J., Burgess, J. L., Robin, M., & Bernard, A. M. (2001) · Respiration Physiology · doi:10.1016/s0034-5687(01)00251-1 · Cited by 30
Metadata
- Authors
- Von Essen, S. G., Scheppers, L. A., Robbins, R. A., & Donham, K. J.
- Venue
- Journal of Toxicology: Clinical Toxicology
- Publisher
- Informa UK Limited
- Published
- 1998-01
- Volume
- 36
- Issue
- 6
- Pages
- 557-565
- ISSN
- 0731-3810 (ISSN-L)
- OpenAlex
- W2131010170
- Cited by
- 52
- References
- 1
- FWCI
- 2.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.