Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 478

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Roentgen stereophotogrammetry: A method for the study of the kinematics of the skeletal system

Open access
Selvik, GÖRan·1989·Acta Orthopaedica Scandinavica

Abstract

I have developed a roentgen stereophotogrammetric method for determination of positions of radiopaque markers in an object. The space coordinates are determined in a laboratory coordinate system, which is defined by markers in a test "cage". The markers in the test cage function as calibration points, and are roentgenographed on the same film(s) as the object. Calibration markers and object markers are exposed from two roentgen foci. The cage markers, are in their function, of two kinds, of which one (fiducial marks) is used for projective transformations of the image points to the laboratory coordinate system, while the other (control points) is used for determining the roentgen foci positions in the same coordinate system. After these calculations have been performed, the three-dimensional coordinates of object indicators are determined by crossing of lines between the roentgen foci and the transformed image points. The mathematical principles for the reconstruction of the bundles of rays from the roentgen foci at the moment of exposure are discussed in Chapter 2. Three constructions of test cages, Models 1A and 1B, and Model 2 are also discussed there. In Test Cage Model 1, the two exposures of the object are obtained on one film, but in Model 2 we expose on two films that are perpendicular to each other. The three cage models are, in turn, intended for high-accuracy determinations of lengths (Model 1A), general determinations of space coordinates, especially in larger objects (Model 1B), and high-accuracy determinations of space coordinates in medium-sized objects (Model 1B), and high-accuracy determinations of space coordinates in medium-sized objects (Model 1B). Note, that if the positions of the roentgen foci and the film are not altered, we can roentgenograph the calibration points separately on a film, and then, after removal of the test cage, roentgenograph the object on the same film. The calibration of the test cages is discussed in Chapter 3. To determine coordinates of markers in a plane is easy, if a rectangular coordinatograph is accessible, and we use the same instrument as for the measurements of the films, a Wild Autograph A8. Determination of the position in space of the plate with control points in relation to the plate with fiducial marks requires more consideration. We describe how the degrees of freedom of the plate with control points (translations in x- and y-directions, rotation angle phi about a z-axis), which are difficult to control at construction of the test cages, can be determined by specific calibration procedures.(ABSTRACT TRUNCATED AT 400 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3109/17453678909154184

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 478

Metadata

Authors
Selvik, G.
Venue
Acta Orthopaedica Scandinavica
Published
1989-01
Volume
60
Issue
sup232
Pages
1-51
ISSN
0001-6470 (ISSN-L)
OpenAlex
W4365787078
Cited by
478
References
5
FWCI
4.47
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Roentgen stereophotogrammetry: A method for the study of the kinematics of the skeletal system. https://app.cochat.ai/papers/10.3109/17453678909154184
The paper
Selvik, G. (1989). Roentgen stereophotogrammetry: A method for the study of the kinematics of the skeletal system. Acta Orthopaedica Scandinavica. https://doi.org/10.3109/17453678909154184

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.