The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Roentgen stereophotogrammetry: A method for the study of the kinematics of the skeletal system
Open accessAbstract
I have developed a roentgen stereophotogrammetric method for determination of positions of radiopaque markers in an object. The space coordinates are determined in a laboratory coordinate system, which is defined by markers in a test "cage". The markers in the test cage function as calibration points, and are roentgenographed on the same film(s) as the object. Calibration markers and object markers are exposed from two roentgen foci. The cage markers, are in their function, of two kinds, of which one (fiducial marks) is used for projective transformations of the image points to the laboratory coordinate system, while the other (control points) is used for determining the roentgen foci positions in the same coordinate system. After these calculations have been performed, the three-dimensional coordinates of object indicators are determined by crossing of lines between the roentgen foci and the transformed image points. The mathematical principles for the reconstruction of the bundles of rays from the roentgen foci at the moment of exposure are discussed in Chapter 2. Three constructions of test cages, Models 1A and 1B, and Model 2 are also discussed there. In Test Cage Model 1, the two exposures of the object are obtained on one film, but in Model 2 we expose on two films that are perpendicular to each other. The three cage models are, in turn, intended for high-accuracy determinations of lengths (Model 1A), general determinations of space coordinates, especially in larger objects (Model 1B), and high-accuracy determinations of space coordinates in medium-sized objects (Model 1B), and high-accuracy determinations of space coordinates in medium-sized objects (Model 1B). Note, that if the positions of the roentgen foci and the film are not altered, we can roentgenograph the calibration points separately on a film, and then, after removal of the test cage, roentgenograph the object on the same film. The calibration of the test cages is discussed in Chapter 3. To determine coordinates of markers in a plane is easy, if a rectangular coordinatograph is accessible, and we use the same instrument as for the measurements of the films, a Wild Autograph A8. Determination of the position in space of the plate with control points in relation to the plate with fiducial marks requires more consideration. We describe how the degrees of freedom of the plate with control points (translations in x- and y-directions, rotation angle phi about a z-axis), which are difficult to control at construction of the test cages, can be determined by specific calibration procedures.(ABSTRACT TRUNCATED AT 400 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mathematical Handbook for Scientists and Engineers
Lieblein, J., Korn, G. A., & Korn, T. M. (1961) · Mathematics of Computation · doi:10.2307/2003035 · Cited by 1,206
A Roentgen Stereophotogrammetric System
Selvik, G., Alberius, P., & Aronson, A. S. (1983) · Acta Radiologica Diagnosis · doi:10.1177/028418518302400412 · Cited by 103
Self-citationAnalytical stereophotogrammetric determination of three-dimensional knee-joint geometry
Huiskes, R., Kremers, J., de Lange, A., Woltring, H. J., Selvik, G., & van Rens, T. J. G. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90011-9 · Cited by 92
Self-citationKinematics of cranial vault growth in rabbits
Alberius, P., & Selvik, G. (1983) · American Journal of Anatomy · doi:10.1002/aja.1001680306 · Cited by 13
Self-citationAlberius, P., Brandt, L., & Selvik, G. (1987) · Journal of Cranio-Maxillofacial Surgery · doi:10.1016/s1010-5182(87)80005-7 · Cited by 10
Self-citation
Cited by
Aseptic loosening, not only a question of wear: A review of different theories
Sundfeldt, M., V Carlsson, L., B Johansson, C., Thomsen, P., & Gretzer, C. (2006) · Acta Orthopaedica · doi:10.1080/17453670610045902 · Cited by 622
Validation of a functional method for the estimation of hip joint centre location
Leardini, A., Cappozzo, A., Catani, F., Toksvig-Larsen, S., Petitto, A., Sforza, V., Cassanelli, G., & Giannini, S. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00148-1 · Cited by 415
Lumbar Intervertebral Instability: A Review
Leone, A., Guglielmi, G., Cassar-Pullicino, V. N., & Bonomo, L. (2007) · Radiology · doi:10.1148/radiol.2451051359 · Cited by 307
Biomechanical behaviours of the bone–implant interface: a review
Gao, X., Fraulob, M., & Haïat, G. (2019) · Journal of The Royal Society Interface · doi:10.1098/rsif.2019.0259 · Cited by 263
Use of Injectable Calcium Phosphate Cement for Fracture Fixation: A Review
Larsson, S., & Bauer, T. W. (2002) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200202000-00004 · Cited by 257
Metadata
- Authors
- Selvik, G.
- Venue
- Acta Orthopaedica Scandinavica
- Published
- 1989-01
- Volume
- 60
- Issue
- sup232
- Pages
- 1-51
- ISSN
- 0001-6470 (ISSN-L)
- OpenAlex
- W4365787078
- Cited by
- 478
- References
- 5
- FWCI
- 4.47
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Roentgen stereophotogrammetry: A method for the study of the kinematics of the skeletal system. https://app.cochat.ai/papers/10.3109/17453678909154184
- The paper
- Selvik, G. (1989). Roentgen stereophotogrammetry: A method for the study of the kinematics of the skeletal system. Acta Orthopaedica Scandinavica. https://doi.org/10.3109/17453678909154184
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.