Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 316

The DOI matches its Crossref record.

A MICROMACHINED VIBRATING RING GYROSCOPE

Open access
Putty, M.W., Najafi, K.·1994·1994 Solid-State, Actuators, and Microsystems Workshop Technical Digest

Abstract

A new micromachined gyroscope based on a vibrating ring is described. The device measures rotation rate or whole angle inertial rotation by monitoring the position of node lines in a vibrating ring. To sense rotation, the ring is electrostatically forced into an elliptically shaped vibration mode and the position of the node lines are capacitively monitored. When the device is rotated about the ring center, the node lines lag behind the rotation due to the Coriolis force. The control and readout circuitry monitors this lag and develops a corrective voltage, that is proportional to the rotation rate, to hold the position of the node lines fixed. In the dissertation a detailed mathematical model of the sensor is developed. This model is used to understand and discuss the operation of the sensor and in the design of the control and readout circuitry. Experimental measurements of the model parameters show good agreement with the theoretical predictions of the device model. To fabricate the sensor, a low-cost process based on metal electroforming techniques was developed that allows large amounts of circuitry to be included with the sensor for signal readout, compensation, autocalibration, and self-test. Using this process sensors, including 3$\mu$m CMOS on-chip buffer amplifiers, have been fabricated. A resolution of approximately 0.5$\sp\circ$/sec in a 10 Hz bandwidth, limited by the on-chip electronics, has been obtained with this new sensor. The zero bias drift of the device was less than 1.5$\sp\circ$/sec over the automotive temperature range while the sensitivity of the device varied by approximately 30% over this same temperature range. Further improvements in the on-chip electronics, the sensor materials, and the sensor design are expected to push the resolution to below 0.1$\sp\circ$/sec in a 50 Hz bandwidth and to improve the temperature performance of the sensor. Recommendations for improving the sensor to meet the requirements for low to medium performance applications are discussed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.31438/trf.hh1994.49

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 316

Metadata

Authors
Putty, M. W., & Najafi, K.
Venue
1994 Solid-State, Actuators, and Microsystems Workshop Technical Digest
Published
1994-06-13
Pages
213-220
OpenAlex
W123268319
Cited by
316
References
0
FWCI
30.86
Type
conference paper
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A MICROMACHINED VIBRATING RING GYROSCOPE. https://app.cochat.ai/papers/10.31438/trf.hh1994.49
The paper
Putty, M. W., & Najafi, K. (1994). A MICROMACHINED VIBRATING RING GYROSCOPE. 1994 Solid-State, Actuators, and Microsystems Workshop Technical Digest. https://doi.org/10.31438/trf.hh1994.49

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.