Evaluation of Formagraph for Comparing Rennet Solutions
Open accessThe DOI matches its Crossref record.
Abstract
A new instrument for measuring milk clotting, the Formagraph, was evaluated.Measurement is movement of small pendulums immersed in linearly oscillating samples of coagulating milk.Pendulum movements are recorded on photographic paper, producing a diagram of firmness versus time.The instrument can he used for measuring milk-clotting enzyme activity in comparison to a standard, and in constrast to the rolling bottle method, it does not require continual observation.Coagulation times measured by the Formagraph are longer than those measured by the rolling bottle method, but both methods give linear standard curves between .2 and 1.0 rennet units/ml enzyme concentrations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Formation and physical properties of milk protein gels
Lucey, J. A. (2002) · Journal of Dairy Science · doi:10.3168/jds.s0022-0302(02)74078-2 · Cited by 667
Silva, S. V., Allmere, T., Xavier Malcata, F., & Andrén, A. (2003) · International Dairy Journal · doi:10.1016/s0958-6946(03)00075-x · Cited by 48
Niero, G., Chiarin, E., Cassandro, M., De Marchi, M., & Penasa, M. (2024) · International Dairy Journal · doi:10.1016/j.idairyj.2023.105820 · Cited by 6
Metadata
- Authors
- McMahon, D. J., & Brown, R. J.
- Venue
- Journal of Dairy Science
- Publisher
- American Dairy Science Association
- Published
- 1982-08
- Volume
- 65
- Issue
- 8
- Pages
- 1639-1642
- ISSN
- 0022-0302 (ISSN-L)
- OpenAlex
- W1664122729
- Cited by
- 232
- References
- 0
- FWCI
- 20.37
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of Formagraph for Comparing Rennet Solutions. https://app.cochat.ai/papers/10.3168/jds.s0022-0302(82)82390-4
- The paper
- McMahon, D. J., & Brown, R. J. (1982). Evaluation of Formagraph for Comparing Rennet Solutions. Journal of Dairy Science. https://doi.org/10.3168/jds.s0022-0302(82)82390-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.