Subthalamic nucleus deep brain stimulator placement using high-field interventional magnetic resonance imaging and a skull-mounted aiming device: technique and application accuracy: Clinical article
Open accessAbstract
Object: The authors discuss their method for placement of deep brain stimulation (DBS) electrodes using interventional MR (iMR) imaging and report on the accuracy of the technique, its initial clinical efficacy, and associated complications in a consecutive series of subthalamic nucleus (STN) DBS implants to treat Parkinson disease (PD). Methods: A skull-mounted aiming device (Medtronic NexFrame) was used in conjunction with real-time MR imaging (Philips Intera 1.5T). Preoperative imaging, DBS implantation, and postimplantation MR imaging were integrated into a single procedure performed with the patient in a state of general anesthesia. Accuracy of implantation was assessed using 2 types of measurements: the “radial error,” defined as the scalar distance between the location of the intended target and the actual location of the guidance sheath in the axial plane 4 mm inferior to the commissures, and the “tip error,” defined as the vector distance between the expected anterior commissure–posterior commissure (AC-PC) coordinates of the permanent DBS lead tip and the actual AC-PC coordinates of the lead tip. Clinical outcome was assessed using the Unified Parkinson's Disease Rating Scale part III (UPDRS III), in the off-medication state. Results: Twenty-nine patients with PD underwent iMR imaging–guided placement of 53 DBS electrodes into the STN. The mean (± SD) radial error was 1.2 ± 0.65 mm, and the mean absolute tip error was 2.2 ± 0.92 mm. The tip error was significantly smaller than for STN DBS electrodes implanted using traditional frame-based stereotaxy (3.1 ± 1.41 mm). Eighty-seven percent of leads were placed with a single brain penetration. No hematomas were visible on MR images. Two device infections occurred early in the series. In bilaterally implanted patients, the mean improvement on the UPDRS III at 9 months postimplantation was 60%. Conclusions: The authors' technical approach to placement of DBS electrodes adapts the procedure to a standard configuration 1.5-T diagnostic MR imaging scanner in a radiology suite. This method simplifies DBS implantation by eliminating the use of the traditional stereotactic frame and the subsequent requirement for registration of the brain in stereotactic space and the need for physiological recording and patient cooperation. This method has improved accuracy compared with that of anatomical guidance using standard frame-based stereotaxy in conjunction with preoperative MR imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Acute and Long-Term Effects of Subthalamic Nucleus Stimulation in Parkinson's Disease
Benabid, A. L., Pollak, P., Gross, C., Hoffmann, D., Benazzouz, A., Gao, D. M., Laurent, A., Gentil, M., & Perret, J. (1994) · Stereotactic and Functional Neurosurgery · doi:10.1159/000098600 · Cited by 532
Plaha, P. (2006) · Brain · doi:10.1093/brain/awl127 · Cited by 515
Rodriguez-Oroz, M. C. (2001) · Brain · doi:10.1093/brain/124.9.1777 · Cited by 466
Okun, M. S., Tagliati, M., Pourfar, M., Fernandez, H. H., Rodriguez, R. L., Alterman, R. L., & Foote, K. D. (2005) · Archives of Neurology · doi:10.1001/archneur.62.8.noc40425 · Cited by 425
Starr, P. A., Christine, C. W., Theodosopoulos, P. V., Lindsey, N., Byrd, D., Mosley, A., & Marks, W. J. (2002) · Journal of Neurosurgery · doi:10.3171/jns.2002.97.2.0370 · Cited by 415
Self-citationDeep brain stimulation: Preoperative issues
Lang, A. E., Houeto, J.-L., Krack, P., Kubu, C., Lyons, K. E., Moro, E., Ondo, W., Pahwa, R., Poewe, W., Tröster, A. I., et al. (2006) · Movement Disorders · doi:10.1002/mds.20955 · Cited by 308
Craniotomy for Tumor Treatment in an Intraoperative Magnetic Resonance Imaging Unit
Black, P. M., Alexander, E., Martin, C., Moriarty, T., Nabavi, A., Wong, T. Z., Schwartz, R. B., & Jolesz, F. (1999) · Neurosurgery · doi:10.1097/00006123-199909000-00001 · Cited by 301
Saint-Cyr, J. A., Hoque, T., Pereira, L. C. M., Dostrovsky, J. O., Hutchison, W. D., Mikulis, D. J., Abosch, A., Sime, E., Lang, A. E., & Lozano, A. M. (2002) · Journal of Neurosurgery · doi:10.3171/jns.2002.97.5.1152 · Cited by 291
Lanotte, M. M. (2002) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.72.1.53 · Cited by 259
Frameless stereotaxy using bone fiducial markers for deep brain stimulation
Holloway, K. L., Gaede, S. E., Starr, P. A., Rosenow, J. M., Ramakrishnan, V., & Henderson, J. M. (2005) · Journal of Neurosurgery · doi:10.3171/jns.2005.103.3.0404 · Cited by 200
Self-citation
Cited by
A Sensitive and Biodegradable Pressure Sensor Array for Cardiovascular Monitoring
Boutry, C. M., Nguyen, A., Lawal, Q. O., Chortos, A., Rondeau‐Gagné, S., & Bao, Z. (2015) · Advanced Materials · doi:10.1002/adma.201502535 · Cited by 647
Val-Laillet, D., Aarts, E., Weber, B., Ferrari, M., Quaresima, V., Stoeckel, L. E., Alonso-Alonso, M., Audette, M., Malbert, C. H., & Stice, E. (2015) · NeuroImage: Clinical · doi:10.1016/j.nicl.2015.03.016 · Cited by 442
Burchiel, K. J., McCartney, S., Lee, A., & Raslan, A. M. (2013) · Journal of Neurosurgery · doi:10.3171/2013.4.jns122324 · Cited by 270
Deep Brain Stimulation: A Paradigm Shifting Approach to Treat Parkinson's Disease
Hickey, P., & Stacy, M. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00173 · Cited by 125
Metadata
- Authors
- Starr, P. A., Martin, A. J., Ostrem, J. L., Talke, P., Levesque, N., & Larson, P. S.
- Venue
- Journal of Neurosurgery
- Published
- 2010-03
- Volume
- 112
- Issue
- 3
- Pages
- 479-490
- ISSN
- 0022-3085 (ISSN-L)
- 1933-0693
- OpenAlex
- W1963534390
- Cited by
- 256
- References
- 22
- FWCI
- 6.56
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Subthalamic nucleus deep brain stimulator placement using high-field interventional magnetic resonance imaging and a skull-mounted aiming device: technique and application accuracy: Clinical article. https://app.cochat.ai/papers/10.3171/2009.6.jns081161
- The paper
- Starr, P. A., Martin, A. J., Ostrem, J. L., Talke, P., Levesque, N., & Larson, P. S. (2010). Subthalamic nucleus deep brain stimulator placement using high-field interventional magnetic resonance imaging and a skull-mounted aiming device: technique and application accuracy: Clinical article. Journal of Neurosurgery. https://doi.org/10.3171/2009.6.jns081161
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.