The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Intraoperative confocal microscopy in the visualization of 5-aminolevulinic acid fluorescence in low-grade gliomas: Clinical article
Abstract
Object: Greater extent of resection (EOR) for patients with low-grade glioma (LGG) corresponds with improved clinical outcome, yet remains a central challenge to the neurosurgical oncologist. Although 5-aminolevulinic acid (5-ALA)–induced tumor fluorescence is a strategy that can improve EOR in gliomas, only glioblastomas routinely fluoresce following 5-ALA administration. Intraoperative confocal microscopy adapts conventional confocal technology to a handheld probe that provides real-time fluorescent imaging at up to 1000× magnification. The authors report a combined approach in which intraoperative confocal microscopy is used to visualize 5-ALA tumor fluorescence in LGGs during the course of microsurgical resection. Methods: Following 5-ALA administration, patients with newly diagnosed LGG underwent microsurgical resection. Intraoperative confocal microscopy was conducted at the following points: 1) initial encounter with the tumor; 2) the midpoint of tumor resection; and 3) the presumed brain-tumor interface. Histopathological analysis of these sites correlated tumor infiltration with intraoperative cellular tumor fluorescence. Results: Ten consecutive patients with WHO Grades I and II gliomas underwent microsurgical resection with 5-ALA and intraoperative confocal microscopy. Macroscopic tumor fluorescence was not evident in any patient. However, in each case, intraoperative confocal microscopy identified tumor fluorescence at a cellular level, a finding that corresponded to tumor infiltration on matched histological analyses. Conclusions: Intraoperative confocal microscopy can visualize cellular 5-ALA–induced tumor fluorescence within LGGs and at the brain-tumor interface. To assess the clinical value of 5-ALA for high-grade gliomas in conjunction with neuronavigation, and for LGGs in combination with intraoperative confocal microscopy and neuronavigation, a Phase IIIa randomized placebo-controlled trial (BALANCE) is underway at the authors' institution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stummer, W., Pichlmeier, U., Meinel, T., Wiestler, O. D., Zanella, F., & Reulen, H.-J. (2006) · The Lancet Oncology · doi:10.1016/s1470-2045(06)70665-9 · Cited by 3,423
Role of extent of resection in the long-term outcome of low-grade hemispheric gliomas
Smith, J. S., Chang, E. F., Lamborn, K. R., Chang, S. M., Prados, M. D., Cha, S., Tihan, T., VandenBerg, S., McDermott, M. W., & Berger, M. S. (2008) · Journal of Clinical Oncology · doi:10.1200/jco.2007.13.9337 · Cited by 1,283
McGirt, M. J., Chaichana, K. L., Attenello, F. J., Weingart, J. D., Than, K., Burger, P. C., Olivi, A., Brem, H., & Quinoñes-Hinojosa, A. (2008) · Neurosurgery · doi:10.1227/01.neu.0000325729.41085.73 · Cited by 533
Cited by
Intraoperative brain cancer detection with Raman spectroscopy in humans
Jermyn, M., Mok, K., Mercier, J., Desroches, J., Pichette, J., Saint-Arnaud, K., Bernstein, L., Guiot, M.-C., Petrecca, K., & Leblond, F. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aaa2384 · Cited by 618
Hadjipanayis, C. G., Widhalm, G., & Stummer, W. (2015) · Neurosurgery · doi:10.1227/neu.0000000000000929 · Cited by 369
Surgical oncology for gliomas: the state of the art
Sanai, N., & Berger, M. S. (2018) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2017.171 · Cited by 332
Self-citationDetection of human brain tumor infiltration with quantitative stimulated Raman scattering microscopy
Ji, M., Lewis, S., Camelo-Piragua, S., Ramkissoon, S. H., Snuderl, M., Venneti, S., Fisher-Hubbard, A., Garrard, M., Fu, D., Wang, A. C., et al. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aab0195 · Cited by 320
Self-citationOppenlander, M. E., Wolf, A. B., Snyder, L. A., Bina, R., Wilson, J. R., Coons, S. W., Ashby, L. S., Brachman, D., Nakaji, P., Porter, R. W., et al. (2014) · Journal of Neurosurgery · doi:10.3171/2013.12.jns13184 · Cited by 266
Self-citation
Metadata
- Authors
- Sanai, N., Snyder, L. A., Honea, N. J., Coons, S. W., Eschbacher, J. M., Smith, K. A., & Spetzler, R. F.
- Venue
- Journal of Neurosurgery
- Published
- 2011-10
- Volume
- 115
- Issue
- 4
- Pages
- 740-748
- ISSN
- 0022-3085 (ISSN-L)
- 1933-0693
- OpenAlex
- W1850380680
- Cited by
- 198
- References
- 3
- FWCI
- 5.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intraoperative confocal microscopy in the visualization of 5-aminolevulinic acid fluorescence in low-grade gliomas: Clinical article. https://app.cochat.ai/papers/10.3171/2011.6.jns11252
- The paper
- Sanai, N., Snyder, L. A., Honea, N. J., Coons, S. W., Eschbacher, J. M., Smith, K. A., & Spetzler, R. F. (2011). Intraoperative confocal microscopy in the visualization of 5-aminolevulinic acid fluorescence in low-grade gliomas: Clinical article. Journal of Neurosurgery. https://doi.org/10.3171/2011.6.jns11252
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.