The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
The Barrow Ruptured Aneurysm Trial: Clinical article
Abstract
Object: The purpose of this ongoing study is to compare the safety and efficacy of microsurgical clipping and endovascular coil embolization for the treatment of acutely ruptured cerebral aneurysms and to determine if one treatment is superior to the other by examining clinical and angiographic outcomes. The authors examined the null hypothesis that no difference exists between the 2 treatment modalities in the setting of subarachnoid hemorrhage (SAH). The current report is limited to the clinical results at 1 year after treatment. Methods: The authors screened 725 patients with SAH, resulting in 500 eligible patients who were enrolled prospectively in the study after giving their informed consent. Patients were assigned in an alternating fashion to surgical aneurysm clipping or endovascular coil therapy. Intake evaluations and outcome measurements were collected by nurse practitioners independent of the treating surgeons. Ultimately, 238 patients were assigned to aneurysm clipping and 233 to coil embolization. The 2 treatment groups were well matched. There were no anatomical exclusions. Crossing over was allowed, but primary outcome analysis was based on the initial treatment modality assignment. Posttreatment care was standardized for both groups. Patient outcomes at 1 year were independently assessed using the modified Rankin Scale (mRS). A poor outcome was defined as an mRS score > 2 at 1 year. The primary outcome was based on the assigned group; that is, by intent to treat. Results: One year after treatment, 403 patients were available for evaluation. Of these, 358 patients had actually undergone treatment. The remainder either died before treatment or had no identifiable source of SAH. A poor outcome (mRS score > 2) was observed in 33.7% of the patients assigned to aneurysm clipping and in 23.2% of the patients assigned to coil embolization (OR 1.68, 95% CI 1.08–2.61; p = 0.02). Of treated patients assigned to the coil group, 124 (62.3%) of the 199 who were eligible for any treatment actually received endovascular coil embolization. Patients who crossed over from coil to clip treatment fared worse than patients assigned to coil embolization, but no worse than patients assigned to clip occlusion. No patient treated by coil embolization suffered a recurrent hemorrhage. Conclusions: One year after treatment, a policy of intent to treat favoring coil embolization resulted in fewer poor outcomes than clip occlusion. Although most aneurysms assigned to the coil treatment group were treated by coil embolization, a substantial number crossed over to surgical clipping. Although a policy of intent to treat favoring coil embolization resulted in fewer poor outcomes at 1 year, it remains important that high-quality surgical clipping be available as an alternative treatment modality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Molyneux, A. J., Kerr, R. S., Yu, L.-M., Clarke, M., Sneade, M., Yarnold, J. A., & Sandercock, P. (2005) · The Lancet · doi:10.1016/s0140-6736(05)67214-5 · Cited by 2,886
Campi, A., Ramzi, N., Molyneux, A. J., Summers, P. E., Kerr, R. S. C., Sneade, M., Yarnold, J. A., Rischmiller, J., & Byrne, J. V. (2007) · Stroke · doi:10.1161/strokeaha.106.466987 · Cited by 553
Koivisto, T., Vanninen, R., Hurskainen, H., Saari, T., Hernesniemi, J., & Vapalahti, M. (2000) · Stroke · doi:10.1161/01.str.31.10.2369 · Cited by 393
The CARAT Investigators* (2006) · Stroke · doi:10.1161/01.str.0000221331.01830.ce · Cited by 306
Ryttlefors, M., Enblad, P., Kerr, R. S. C., & Molyneux, A. J. (2008) · Stroke · doi:10.1161/strokeaha.107.506030 · Cited by 216
Durability of Aneurysm Embolization with Matrix Detachable Coils
Fiorella, D. J., Albuquerque, F. C., & McDougall, C. G. (2005) · Neurosurgery · doi:10.1227/01.neu.0000194190.45595.9e · Cited by 124
Self-citationEndosaccular Treatment of Intracranial Aneurysms Using Matrix Coils
Niimi, Y., Song, J. K., Madrid, M., & Berenstein, A. (2006) · Stroke · doi:10.1161/01.str.0000206459.73897.a3 · Cited by 111
Derdeyn, C. P., Barr, J. D., Berenstein, A., Connors, J. J. “., Dion, J. E., Duckwiler, G., Higashida, R. T., Strother, C. M., Tomsick, T. A., & Turski, P. A. (2003) · PubMed Central · Cited by 67
Harbaugh, R. E., Heros, R. C., & Hadley, M. N. (2003) · The Lancet · doi:10.1016/s0140-6736(03)12641-4 · Cited by 55
Cited by
Hoh, B. L., Ko, N. U., Amin-Hanjani, S., Chou, S. H.-Y., Cruz-Flores, S., Dangayach, N. S., Derdeyn, C. P., Du, R., Hänggi, D., Hetts, S. W., et al. (2023) · Stroke · doi:10.1161/str.0000000000000436 · Cited by 1,000
Unruptured intracranial aneurysms: development, rupture and preventive management
Etminan, N., & Rinkel, G. J. (2016) · Nature Reviews Neurology · doi:10.1038/nrneurol.2016.150 · Cited by 632
Saatci, I., Yavuz, K., Ozer, C., Geyik, S., & Cekirge, H. S. (2012) · American Journal of Neuroradiology · doi:10.3174/ajnr.a3246 · Cited by 368
Clipping Versus Coiling for Ruptured Intracranial Aneurysms: A Systematic Review and Meta-Analysis
Li, H., Pan, R., Wang, H., Rong, X., Yin, Z., Milgrom, D. P., Shi, X., Tang, Y., & Peng, Y. (2013) · Stroke · doi:10.1161/strokeaha.112.663559 · Cited by 287
Peng, Q., Wang, S., Han, J., Huang, C., Yu, H., Li, D., Qiu, M., Cheng, S., Wu, C., Cai, M., et al. (2024) · Research · doi:10.34133/research.0339 · Cited by 89
Metadata
- Authors
- McDougall, C. G., Spetzler, R. F., Zabramski, J. M., Partovi, S., Hills, N. K., Nakaji, P., & Albuquerque, F. C.
- Venue
- Journal of Neurosurgery
- Published
- 2012-01
- Volume
- 116
- Issue
- 1
- Pages
- 135-144
- ISSN
- 0022-3085 (ISSN-L)
- 1933-0693
- OpenAlex
- W2144792598
- Cited by
- 647
- References
- 10
- FWCI
- 27.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Barrow Ruptured Aneurysm Trial: Clinical article. https://app.cochat.ai/papers/10.3171/2011.8.jns101767
- The paper
- McDougall, C. G., Spetzler, R. F., Zabramski, J. M., Partovi, S., Hills, N. K., Nakaji, P., & Albuquerque, F. C. (2012). The Barrow Ruptured Aneurysm Trial: Clinical article. Journal of Neurosurgery. https://doi.org/10.3171/2011.8.jns101767
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.