CoChat

Management of device-related wound complications in deep brain stimulation surgery: Clinical article

Fenoy, Albert J., Simpson, Richard K. · 2012 · Journal of Neurosurgery
Cited by 115

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Object: Wound complications are uncommon following deep brain stimulation (DBS) surgery. However, certain key technical steps can be performed in each procedure to minimize this still troublesome risk. The authors reviewed the incidence and management of all hardware-related wound dehiscences and infections in a large patient series. Methods: All patients undergoing new DBS hardware implantation surgery between 2002 and 2010 by a single surgeon (R.K.S.) were entered into a database after undergoing verification by cross-referencing manufacturer implantation records. All hardware-related complications such as wound dehiscence, erosions, and/or infections were identified, and wound location, time of incidence, and mechanism were categorized. Charts were reviewed to evaluate the success of conservative treatment versus partial or total hardware removal. Results: Seven hundred twenty-eight patients received 1333 new DBS leads and 1218 new implantable pulse generators (IPGs) in a total of 1356 stereotactic procedures for movement disorders. Seventy-eight percent of patients underwent staged lead and IPG implantations. Sixteen patients presented with atraumatic device-related infection and/or dehiscence within 12 months from original implantation; 9 of these patients (1.24%) required additional surgery after antibiotic failure. All 8 patients presenting with cranial wound complications were treated initially by debridement in an attempt to salvage the leads; debridement followed by intravenous antibiotics was only successful in 2 patients presenting with dehiscence alone. One of 2 lead-only removals was successful in infections originating in the cranium; the only IPG-originating infection was treated by partial hardware removal and intravenous antibiotics. Two of 637 IPG replacements resulted in infections within 12 months after revision, requiring either partial or total hardware removal, while 1 dehiscence in this group was treated by debridement alone. Conclusions: In a large series of new DBS hardware implantations, the incidence of postoperative wound dehiscence and/or infections requiring further surgery was 1.24%. Standard practice for all implantations was a short procedural duration, copious povidone-iodine irrigation, and postoperative antibiotic administration. Partial hardware removal should be initially attempted for infection. Debridement alone is successful in treating dehiscence without infection.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3171/2012.1.jns111798

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 115

Metadata

Authors
Fenoy, A. J., & Simpson, R. K.
Venue
Journal of Neurosurgery
Published
2012-06
Volume
116
Issue
6
Pages
1324-1332
ISSN
  • 0022-3085 (ISSN-L)
  • 1933-0693
OpenAlex
W1496041048
Cited by
115
References
1
FWCI
4.86
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.