The DOI matches its Crossref record.
Stereotactic placement of depth electrodes in medically intractable epilepsy: Technical note
Abstract
Object: Despite its long-reported successful record, with almost 60 years of clinical use, the technical complexity regarding the placement of stereoelectroencephalography (SEEG) depth electrodes may have contributed to the limited widespread application of the technique in centers outside Europe. The authors report on a simplified and novel SEEG surgical technique in the extraoperative mapping of refractory focal epilepsy. Methods: The proposed technique was applied in patients with medically refractory focal epilepsy. Data regarding general demographic information, method of electrode implantation, time of implantation, number of implanted electrodes, seizure outcome after SEEG-guided resections, and complications were prospectively collected. Results: From March 2009 to April 2012, 122 patients underwent SEEG depth electrode implantation at the Cleveland Clinic Epilepsy Center in which the authors' technique was used. There were 65 male and 57 female patients whose mean age was 33 years (range 5–68 years). The group included 21 pediatric patients (younger than 18 years). Planning and implantations were performed in a single stage. The time for planning was, on average, 33 minutes (range 20–47 minutes), and the time for implantation was, on average, 107 minutes (range 47–150 minutes). Complications related to the SEEG technique were observed in 3 patients. The calculated risk of complications per electrode was 0.18%. The seizure-free rate after SEEG-guided resections was 62% in a mean follow-up period of 12 months. Conclusions: The authors report on a safe, simplified, and less time-consuming method of SEEG depth electrode implantation, using standard and widely available surgical tools, making the technique a reasonable option for extraoperative monitoring of patients with medically intractable epilepsy in centers lacking the Talairach stereotactic armamentarium.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Epilepsy surgery in children and adults
Ryvlin, P., Cross, J. H., & Rheims, S. (2014) · The Lancet Neurology · doi:10.1016/s1474-4422(14)70156-5 · Cited by 501
Mullin, J. P., Shriver, M., Alomar, S., Najm, I., Bulacio, J., Chauvel, P., & Gonzalez‐Martinez, J. (2016) · Epilepsia · doi:10.1111/epi.13298 · Cited by 434
Self-citationTechnique, Results, and Complications Related to Robot-Assisted Stereoelectroencephalography
González-Martínez, J., Bulacio, J., Thompson, S., Gale, J., Smithason, S., Najm, I., & Bingaman, W. (2016) · Neurosurgery · doi:10.1227/neu.0000000000001034 · Cited by 315
Self-citationElectrocorticography and functional mapping
(2019) · Handbook of Clinical Neurology · doi:10.1016/b978-0-444-64032-1.00020-5 · Cited by 28
Bullock, L., Forseth, K. J., Woolnough, O., Rollo, P. S., & Tandon, N. (2023) · doi:10.1101/2023.04.04.535557 · Cited by 2
Metadata
- Authors
- Gonzalez-Martinez, J., Mullin, J., Vadera, S., Bulacio, J., Hughes, G., Jones, S., Enatsu, R., & Najm, I.
- Venue
- Journal of Neurosurgery
- Published
- 2014-03
- Volume
- 120
- Issue
- 3
- Pages
- 639-644
- ISSN
- 0022-3085 (ISSN-L)
- 1933-0693
- OpenAlex
- W1957621647
- Cited by
- 209
- References
- 0
- FWCI
- 15.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Stereotactic placement of depth electrodes in medically intractable epilepsy: Technical note. https://app.cochat.ai/papers/10.3171/2013.11.jns13635
- The paper
- Gonzalez-Martinez, J., Mullin, J., Vadera, S., Bulacio, J., Hughes, G., Jones, S., Enatsu, R., & Najm, I. (2014). Stereotactic placement of depth electrodes in medically intractable epilepsy: Technical note. Journal of Neurosurgery. https://doi.org/10.3171/2013.11.jns13635
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.