Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 209

The DOI matches its Crossref record.

Stereotactic placement of depth electrodes in medically intractable epilepsy: Technical note

Gonzalez-Martinez, Jorge, Mullin, Jeffrey, Vadera, Sumeet, Bulacio, Juan, Hughes, Gwyneth, Jones, Stephen, Enatsu, Rei, Najm, Imad · 2014 · Journal of Neurosurgery

Abstract

Object: Despite its long-reported successful record, with almost 60 years of clinical use, the technical complexity regarding the placement of stereoelectroencephalography (SEEG) depth electrodes may have contributed to the limited widespread application of the technique in centers outside Europe. The authors report on a simplified and novel SEEG surgical technique in the extraoperative mapping of refractory focal epilepsy. Methods: The proposed technique was applied in patients with medically refractory focal epilepsy. Data regarding general demographic information, method of electrode implantation, time of implantation, number of implanted electrodes, seizure outcome after SEEG-guided resections, and complications were prospectively collected. Results: From March 2009 to April 2012, 122 patients underwent SEEG depth electrode implantation at the Cleveland Clinic Epilepsy Center in which the authors' technique was used. There were 65 male and 57 female patients whose mean age was 33 years (range 5–68 years). The group included 21 pediatric patients (younger than 18 years). Planning and implantations were performed in a single stage. The time for planning was, on average, 33 minutes (range 20–47 minutes), and the time for implantation was, on average, 107 minutes (range 47–150 minutes). Complications related to the SEEG technique were observed in 3 patients. The calculated risk of complications per electrode was 0.18%. The seizure-free rate after SEEG-guided resections was 62% in a mean follow-up period of 12 months. Conclusions: The authors report on a safe, simplified, and less time-consuming method of SEEG depth electrode implantation, using standard and widely available surgical tools, making the technique a reasonable option for extraoperative monitoring of patients with medically intractable epilepsy in centers lacking the Talairach stereotactic armamentarium.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3171/2013.11.jns13635

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 209

Metadata

Authors
Gonzalez-Martinez, J., Mullin, J., Vadera, S., Bulacio, J., Hughes, G., Jones, S., Enatsu, R., & Najm, I.
Venue
Journal of Neurosurgery
Published
2014-03
Volume
120
Issue
3
Pages
639-644
ISSN
  • 0022-3085 (ISSN-L)
  • 1933-0693
OpenAlex
W1957621647
Cited by
209
References
0
FWCI
15.72
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Stereotactic placement of depth electrodes in medically intractable epilepsy: Technical note. https://app.cochat.ai/papers/10.3171/2013.11.jns13635
The paper
Gonzalez-Martinez, J., Mullin, J., Vadera, S., Bulacio, J., Hughes, G., Jones, S., Enatsu, R., & Najm, I. (2014). Stereotactic placement of depth electrodes in medically intractable epilepsy: Technical note. Journal of Neurosurgery. https://doi.org/10.3171/2013.11.jns13635

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.