The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Quantitative fluorescence using 5-aminolevulinic acid-induced protoporphyrin IX biomarker as a surgical adjunct in low-grade glioma surgery
Open accessAbstract
OBJECT: Previous studies in high-grade gliomas (HGGs) have indicated that protoporphyrin IX (PpIX) accumulates in higher concentrations in tumor tissue, and, when used to guide surgery, it has enabled improved resection leading to increased progression-free survival. Despite the benefits of complete resection and the advances in fluorescence-guided surgery, few studies have investigated the use of PpIX in low-grade gliomas (LGGs). Here, the authors describe their initial experience with 5-aminolevulinic acid (ALA)-induced PpIX fluorescence in a series of patients with LGG. METHODS: Twelve patients with presumed LGGs underwent resection of their tumors after receiving 20 mg/kg of ALA approximately 3 hours prior to surgery under an institutional review board-approved protocol. Intraoperative assessments of the resulting PpIX emissions using both qualitative, visible fluorescence and quantitative measurements of PpIX concentration were obtained from tissue locations that were subsequently biopsied and evaluated histopathologically. Mixed models for random effects and receiver operating characteristic curve analysis for diagnostic performance were performed on the fluorescence data relative to the gold-standard histopathology. RESULTS: Five of the 12 LGGs (1 ganglioglioma, 1 oligoastrocytoma, 1 pleomorphic xanthoastrocytoma, 1 oligodendroglioma, and 1 ependymoma) demonstrated at least 1 instance of visible fluorescence during surgery. Visible fluorescence evaluated on a specimen-by-specimen basis yielded a diagnostic accuracy of 38.0% (cutoff threshold: visible fluorescence score ≥ 1, area under the curve = 0.514). Quantitative fluorescence yielded a diagnostic accuracy of 67% (for a cutoff threshold of the concentration of PpIX [C PpIX] > 0.0056 μg/ml, area under the curve = 0.66). The authors found that 45% (9/20) of nonvisibly fluorescent tumor specimens, which would have otherwise gone undetected, accumulated diagnostically significant levels of C PpIX that were detected quantitatively. CONCLUSIONS: The authors’ initial experience with ALA-induced PpIX fluorescence in LGGs concurs with other literature reports that the resulting visual fluorescence has poor diagnostic accuracy. However, the authors also found that diagnostically significant levels of C PpIX do accumulate in LGGs, and the resulting fluorescence emissions are very often below the detection threshold of current visual fluorescence imaging methods. Indeed, at least in the authors’ initial experience reported here, if quantitative detection methods are deployed, the diagnostic performance of ALA-induced PpIX fluorescence in LGGs approaches the accuracy associated with visual fluorescence in HGGs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stummer, W., Pichlmeier, U., Meinel, T., Wiestler, O. D., Zanella, F., & Reulen, H.-J. (2006) · The Lancet Oncology · doi:10.1016/s1470-2045(06)70665-9 · Cited by 3,423
Role of extent of resection in the long-term outcome of low-grade hemispheric gliomas
Smith, J. S., Chang, E. F., Lamborn, K. R., Chang, S. M., Prados, M. D., Cha, S., Tihan, T., VandenBerg, S., McDermott, M. W., & Berger, M. S. (2008) · Journal of Clinical Oncology · doi:10.1200/jco.2007.13.9337 · Cited by 1,283
Stummer, W., Novotny, A., Stepp, H., Goetz, C., Bise, K., & Reulen, H. J. (2000) · Journal of Neurosurgery · doi:10.3171/jns.2000.93.6.1003 · Cited by 881 · cited 3×
“1,7,10,11,13,15,17,20,29,30,34,35,41,47,49,52 However, the vast majority of clinical studies on fluorescence-guided neuro - surgery have only considered the qualitative, visible PpIX emissions.”
McGirt, M. J., Chaichana, K. L., Attenello, F. J., Weingart, J. D., Than, K., Burger, P. C., Olivi, A., Brem, H., & Quinoñes-Hinojosa, A. (2008) · Neurosurgery · doi:10.1227/01.neu.0000325729.41085.73 · Cited by 533
Cited by
DSouza, A. V., Lin, H., Henderson, E. R., Samkoe, K. S., & Pogue, B. W. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.8.080901 · Cited by 414
5‐ALA in the management of malignant glioma
Stepp, H., & Stummer, W. (2018) · Lasers in Surgery and Medicine · doi:10.1002/lsm.22933 · Cited by 234
Tumor treating fields increases membrane permeability in glioblastoma cells
Chang, E., Patel, C. B., Pohling, C., Young, C., Song, J., Flores, T. A., Zeng, Y., Joubert, L.-M., Arami, H., Natarajan, A., et al. (2018) · Cell Death Discovery · doi:10.1038/s41420-018-0130-x · Cited by 137
Visualization technologies for 5-ALA-based fluorescence-guided surgeries
Wei, L., Roberts, D. W., Sanai, N., & Liu, J. T. C. (2019) · Journal of Neuro-Oncology · doi:10.1007/s11060-018-03077-9 · Cited by 67
Self-citationBravo, J. J., Olson, J. D., Davis, S. C., Roberts, D. W., Paulsen, K. D., & Kanick, S. C. (2017) · Scientific Reports · doi:10.1038/s41598-017-09727-8 · Cited by 53
Self-citation
Metadata
- Authors
- Valdés, P. A., Jacobs, V., Harris, B. T., Wilson, B. C., Leblond, F., Paulsen, K. D., & Roberts, D. W.
- Venue
- Journal of Neurosurgery
- Published
- 2015-09
- Volume
- 123
- Issue
- 3
- Pages
- 771-780
- ISSN
- 0022-3085 (ISSN-L)
- 1933-0693
- OpenAlex
- W1680005262
- Cited by
- 170
- References
- 4
- FWCI
- 7.34
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative fluorescence using 5-aminolevulinic acid-induced protoporphyrin IX biomarker as a surgical adjunct in low-grade glioma surgery. https://app.cochat.ai/papers/10.3171/2014.12.jns14391
- The paper
- Valdés, P. A., Jacobs, V., Harris, B. T., Wilson, B. C., Leblond, F., Paulsen, K. D., & Roberts, D. W. (2015). Quantitative fluorescence using 5-aminolevulinic acid-induced protoporphyrin IX biomarker as a surgical adjunct in low-grade glioma surgery. Journal of Neurosurgery. https://doi.org/10.3171/2014.12.jns14391
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.