The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Chronic electrocorticography for sensing movement intention and closed-loop deep brain stimulation with wearable sensors in an essential tremor patient
Open accessAbstract
Deep brain stimulation (DBS) has become a widespread and valuable treatment for patients with movement disorders such as essential tremor (ET). However, current DBS treatment constantly delivers stimulation in an open loop, which can be inefficient. Closing the loop with sensors to provide feedback may increase power efficiency and reduce side effects for patients. New implantable neuromodulation platforms, such as the Medtronic Activa PC+S DBS system, offer important data sources by providing chronic neural sensing capabilities and a means of investigating dynamic stimulation based on symptom measurements. The authors implanted in a single patient with ET an Activa PC+S system, a cortical strip of electrodes on the hand sensorimotor cortex, and therapeutic electrodes in the ventral intermediate nucleus of the thalamus. In this paper they describe the effectiveness of the platform when sensing cortical movement intentions while the patient actually performed and imagined performing movements. Additionally, they demonstrate dynamic closed-loop DBS based on several wearable sensor measurements of tremor intensity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optimal spatial filtering of single trial EEG during imagined hand movement
Ramoser, H., Muller-Gerking, J., & Pfurtscheller, G. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.895946 · Cited by 2,457
Perlmutter, J. S., & Mink, J. W. (2006) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.29.051605.112824 · Cited by 1,073
Patterns of cortical activation during planning of voluntary movement
Pfurtscheller, G., & Berghold, A. (1989) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(89)90250-2 · Cited by 520
Burchiel, K. J., McCartney, S., Lee, A. E., & Raslan, A. M. T. (2013) · Journal of neurosurgery · doi:10.3171/2013.4.jns122324 · Cited by 271
Oscillations in sensorimotor cortex in movement disorders: an electrocorticography study
Crowell, A. L., Ryapolova-Webb, E. S., Ostrem, J. L., Galifianakis, N. B., Shimamoto, S. A., Lim, D. A., & Starr, P. A. (2012) · Brain · doi:10.1093/brain/awr332 · Cited by 179
Kinematic Adaptive Deep Brain Stimulation for Resting Tremor in Parkinson's Disease
Malekmohammadi, M., Herron, J., Velisar, A., Blumenfeld, Z., Trager, M. H., Chizeck, H. J., & Brontë‐Stewart, H. (2016) · Movement Disorders · doi:10.1002/mds.26482 · Cited by 134
Self-citationClinical response to varying the stimulus parameters in deep brain stimulation for essential tremor
Kuncel, A. M., Cooper, S. E., Wolgamuth, B. R., Clyde, M. A., Snyder, S. A., Montgomery, E. B., Rezai, A. R., & Grill, W. M. (2006) · Movement Disorders · doi:10.1002/mds.21087 · Cited by 122
Clinical update: diagnosis and treatment of essential tremor
Benito‐León, J., & Louis, E. D. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60544-3 · Cited by 120
Hebb, A. O., Zhang, J. J., Mahoor, M. H., Tsiokos, C., Matlack, C., Chizeck, H. J., & Pouratian, N. (2013) · Neurosurgery Clinics of North America · doi:10.1016/j.nec.2013.08.006 · Cited by 119
Self-citationOn-Demand Control System for Deep Brain Stimulation for Treatment of Intention Tremor
Yamamoto, T., Katayama, Y., Ushiba, J., Yoshino, H., Obuchi, T., Kobayashi, K., Oshima, H., & Fukaya, C. (2013) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/j.1525-1403.2012.00521.x · Cited by 90
8th International IEEE EMBS Conference on Neural Engineering
(2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2633219 · Cited by 82
Closed-loop DBS with movement intention
Herron, J. A., Denison, T., & Chizeck, H. J. (2015) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2015.7146755 · Cited by 36
Self-citationPrototype closed-loop deep brain stimulation systems inspired by Norbert Wiener
Herron, J. A., & Chizeck, H. J. (2014) · IEEE Conference on Norbert Wiener in the 21st Century (21CW) · doi:10.1109/norbert.2014.6893922 · Cited by 19
Self-citationA Metric for Evaluating and Comparing Closed-Loop Deep Brain Stimulation AlgorithmsPreprint
Herron, J. A., Velisar, A., Malekmohammadi, M., Bronte-Stewart, H. M., & Chizeck, H. J. (2016) · arXiv (Cornell University) · doi:10.48550/arxiv.1605.09312 · Cited by 2
Self-citation
Cited by
Sorted by citations
Technology of deep brain stimulation: current status and future directions
Krauss, J. K., Lipsman, N., Aziz, T. Z., Boutet, A., Brown, P., Chang, J. W., Davidson, B., Grill, W. M., Hariz, M. I., Horn, A., et al. (2020) · Nature Reviews Neurology · doi:10.1038/s41582-020-00426-z · Cited by 930
Gilron, R., Little, S., Perrone, R., Wilt, R., de Hemptinne, C., Yaroshinsky, M. S., Racine, C. A., Wang, S. S., Ostrem, J. L., Larson, P. S., et al. (2021) · Nature Biotechnology · doi:10.1038/s41587-021-00897-5 · Cited by 343
Emerging technologies for improved deep brain stimulation
Cagnan, H., Denison, T., McIntyre, C. C., & Brown, P. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0244-6 · Cited by 274
Jakobs, M., Fomenko, A., Lozano, A. M., & Kiening, K. L. (2019) · EMBO Molecular Medicine · doi:10.15252/emmm.201809575 · Cited by 232
Deep Brain Stimulation in Movement Disorders: From Experimental Surgery to Evidence‐Based Therapy
Krack, P., Volkmann, J., Tinkhauser, G., & Deuschl, G. (2019) · Movement Disorders · doi:10.1002/mds.27860 · Cited by 186
Metadata
- Authors
- Herron, J. A., Thompson, M. C., Brown, T., Chizeck, H. J., Ojemann, J. G., & Ko, A. L.
- Affiliations
- U.S. National Science Foundation (US)
- ORCID
- Venue
- Journal of Neurosurgery
- Published
- 2017-09
- Volume
- 127
- Issue
- 3
- Pages
- 580-587
- ISSN
- 0022-3085 (ISSN-L)
- 1933-0693
- OpenAlex
- W2556228493
- Semantic Scholar
- 07b5bcc93073bae9ff055d42c3cdaaffed19a0df
- Cited by
- 139
- References
- 14
- Citations by year
- 2026: 5 · 2025: 10 · 2024: 12 · 2023: 17 · 2022: 13 · 2021: 22 · 2020: 22 · 2019: 13 · 2018: 17 · 2017: 8
- FWCI
- 9.52
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of neurosurgery (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation (EEC-1 028725, 1028725)
- U.S. Department of Defense
- National Defense Science and Engineering Graduate
- Topics
- Health Sciences › Medicine › Clinical Neurology › Deep Brain Stimulation and Movement Disorders
- Social Sciences › Psychology › Clinical Psychology › Obsessive-Compulsive Spectrum Disorders
- Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
- Keywords
- essential tremor, deep brain stimulation, closed-loop stimulation, wearable sensors, ventral intermediate nucleus, movement intention
- MeSH terms
- Electrocorticography, Electrodes, Equipment Design, Humans, Male, Middle Aged, Movement, Essential Tremor, Intention, Deep Brain Stimulation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review