CoChat
Cited by 210

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Current applications of robotics in spine surgery: a systematic review of the literature

Open access
Joseph, Jacob R., Smith, Brandon W., Liu, Xilin, Park, Paul · 2017 · Neurosurgical Focus

Abstract

OBJECTIVE: Surgical robotics has demonstrated utility across the spectrum of surgery. Robotics in spine surgery, however, remains in its infancy. Here, the authors systematically review the evidence behind robotic applications in spinal instrumentation. METHODS: This systematic review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines. Relevant studies (through October 2016) that reported the use of robotics in spinal instrumentation were identified from a search of the PubMed database. Data regarding the accuracy of screw placement, surgeon learning curve, radiation exposure, and reasons for robotic failure were extracted. RESULTS: Twenty-five studies describing 2 unique robots met inclusion criteria. Of these, 22 studies evaluated accuracy of spinal instrumentation. Although grading of pedicle screw accuracy was variable, the most commonly used method was the Gertzbein and Robbins system of classification. In the studies using the Gertzbein and Robbins system, accuracy (Grades A and B) ranged from 85% to 100%. Ten studies evaluated radiation exposure during the procedure. In studies that detailed fluoroscopy usage, overall fluoroscopy times ranged from 1.3 to 34 seconds per screw. Nine studies examined the learning curve for the surgeon, and 12 studies described causes of robotic failure, which included registration failure, soft-tissue hindrance, and lateral skiving of the drill guide. CONCLUSIONS: Robotics in spine surgery is an emerging technology that holds promise for future applications. Surgical accuracy in instrumentation implanted using robotics appears to be high. However, the impact of robotics on radiation exposure is not clear and seems to be dependent on technique and robot type.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3171/2017.2.focus16544

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Metadata

Authors
Joseph, J. R., Smith, B. W., Liu, X., & Park, P.
Venue
Neurosurgical Focus
Published
2017-05
Volume
42
Issue
5
Pages
E2
ISSN
1092-0684 (ISSN-L)
OpenAlex
W2610741098
Cited by
210
References
1
FWCI
4.04
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Current applications of robotics in spine surgery: a systematic review of the literature. https://app.cochat.ai/papers/10.3171/2017.2.focus16544
The paper
Joseph, J. R., Smith, B. W., Liu, X., & Park, P. (2017). Current applications of robotics in spine surgery: a systematic review of the literature. Neurosurgical Focus. https://doi.org/10.3171/2017.2.focus16544

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.