CoChat

Validation of the visual analog scale in the cervical spine

Open access
MacDowall, Anna, Skeppholm, Martin, Robinson, Yohan, Olerud, Claes · 2018 · Journal of Neurosurgery: Spine
Cited by 159

The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: The visual analog scale (VAS) is frequently used to measure treatment outcome in patients with cervical spine disorders. The minimum clinically important difference (MCID) is the smallest change in a score that has clinical importance to the patient. Although it has been established for other medical fields, knowledge of the VAS MCID for the cervical spine is sparse, and it has rarely been considered in relation to measurement noise. The goals in this study were as follows: 1) to validate the VAS-neck and VAS-arm instruments for the cervical spine (e.g., repeatability); 2) to investigate the possible influence of predictive factors and the Hospital Anxiety and Depression Scale (HADS) score on repeatability; and 3) to compute the MCID with 5 different methods. METHODS: A post hoc analysis of a prospective randomized controlled trial with 151 patients undergoing surgery for cervical radiculopathy due to degenerative disc disease was performed. Information on age, sex, smoking habits, exercise, employment status, HADS score, and VAS-neck and VAS-arm scores was gathered before surgery and after 1 year. The VAS was applied twice on every occasion, with 15 minutes in between. Repeatability and the association with predictors and HADS score were analyzed using the 1-sample t-test, linear regression models, and Spearman correlation. The MCID was calculated with the following methods: average change, change difference, receiver operating characteristic curve, effect size, and minimum detectable change (MDC). RESULTS: The repeatability in VAS-neck was 8.1 mm, and in VAS-arm it was 10.4 mm. Less consistent values on the VAS correlated to female sex and higher values on the HADS. For VAS-neck the MCID ranged from 4.6 to 21.4, and for VAS-arm it ranged from 1.1 to 29.1. The highest MCID came from the MDC method, which was the only method that gave values above the measurement noise in both VAS-neck and VAS-arm. CONCLUSIONS: Measurement noise in VAS-neck and VAS-arm for the cervical spine was influenced by female sex and HADS score. The only method to compute MCID that consistently gave results above the measurement noise in VAS-neck and VAS-arm was the MDC. Clinical trial registration no.: 44347115 (www.isrctn.com).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3171/2017.5.spine1732

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 31 references

Cited by

Metadata

Authors
MacDowall, A., Skeppholm, M., Robinson, Y., & Olerud, C.
Venue
Journal of Neurosurgery: Spine
Published
2018-03
Volume
28
Issue
3
Pages
227-235
ISSN
  • 1547-5646 (ISSN-L)
  • 1547-5654
OpenAlex
W2773496679
Cited by
159
References
31
FWCI
3.43
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.