The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Cerebral blood flow measurements and electroencephalograms during carotid endarterectomy
Abstract
✓ Ninety-three endarterectomies for carotid stenosis were monitored with cerebral blood flow (CBF) measurements, and 113 with both CBF measurements and a continuous electroencephalogram (EEG). Significant CBF increase occurred only when carotid endarterectomy was for a stenosis greater than 90%. A high correlation between CBF and EEG indicated when a shunt was required. To sustain a normal EEG, the CBF ascertained by the initial slope technique must be 18 ml/100 gm/min at an arterial carbon dioxide tension (PaCO 2) of 40 torr. The degree of EEG change below this level during occlusion reflected the severity of reduced blood flow and was reversible with replacement of a shunt. The value and limitations of these monitoring techniques and a concept of ischemic tolerance and critical CBF are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cerebral ischemia. II. The no-reflow phenomenon.
Ames, A., Rl, W., Kowada, M., Thurston, J. M., & Majno, G. (1968) · PubMed · Cited by 1,371
Lassen, N. A. (1966) · The Lancet · doi:10.1016/s0140-6736(66)92199-4 · Cited by 912
SHARBROUGH, F. W., MESSICK, J. M., & SUNDT, T. M. (1973) · Stroke · doi:10.1161/01.str.4.4.674 · Cited by 489
Self-citationCarotid Endarterectomy for Cerebrovascular Insufficiency
Thompson, J. E., Austin, D. J., & Patman, R. D. (1970) · Annals of Surgery · doi:10.1097/00000658-197010000-00012 · Cited by 292
Regional cerebral blood flow in man determined by krypton 85
Lassen, N. A., Høledt-Hasmussen, K., Søremen, S. C., Skinhøj, E., Cronquist, S., Bodforss, B., Eng, E., & Ingvar, D. H. (1963) · Neurology · doi:10.1212/wnl.13.9.719 · Cited by 290
Restoration of Middle Cerebral Artery Flow in Experimental Infarction
Sundt, T. M., Grant, W. C., & Garcia, J. H. (1969) · Journal of Neurosurgery · doi:10.3171/jns.1969.31.3.0311 · Cited by 215
Self-citationCerebral Ischemia and Reactive Hyperemia
Sundt, T. M., & Waltz, A. G. (1971) · Circulation Research · doi:10.1161/01.res.28.4.426 · Cited by 128
Self-citationCerebral Vascular Diseases: Eighth Conference.
Bank, A. A. (1974) · Archives of Internal Medicine · doi:10.1001/archinte.1974.00320190191061 · Cited by 12
Cited by
Thresholds in cerebral ischemia - the ischemic penumbra.
Astrup, J., Siesjö, B. K., & Symon, L. (1981) · Stroke · doi:10.1161/01.str.12.6.723 · Cited by 2,820
Baron, J. C., Bousser, M. G., Rey, A., Guillard, A., Comar, D., & Castaigne, P. (1981) · Stroke · doi:10.1161/01.str.12.4.454 · Cited by 724
Nagasawa, H., & Kogure, K. (1989) · Stroke · doi:10.1161/01.str.20.8.1037 · Cited by 522
Powers, W. J., Grubb, R. L., Darriet, D., & Raichle, M. E. (1985) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1985.89 · Cited by 425
Garcia, J. H., Liu, K.-F., & Ho, K.-L. (1995) · Stroke · doi:10.1161/01.str.26.4.636 · Cited by 361
Metadata
- Authors
- Sundt, T. M., Sharbrough, F. W., Anderson, R. E., & Michenfelder, J. D.
- Venue
- Journal of Neurosurgery
- Published
- 1974-09
- Volume
- 41
- Issue
- 3
- Pages
- 310-320
- ISSN
- 0022-3085 (ISSN-L)
- OpenAlex
- W2347244514
- Cited by
- 353
- References
- 8
- FWCI
- 16.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cerebral blood flow measurements and electroencephalograms during carotid endarterectomy. https://app.cochat.ai/papers/10.3171/jns.1974.41.3.0310
- The paper
- Sundt, T. M., Sharbrough, F. W., Anderson, R. E., & Michenfelder, J. D. (1974). Cerebral blood flow measurements and electroencephalograms during carotid endarterectomy. Journal of Neurosurgery. https://doi.org/10.3171/jns.1974.41.3.0310
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.