Factors causing acute shunt infection: Computer analysis of 1174 operations
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
✓ A series of 1174 operations performed on 802 hydrocephalic children was analyzed in an effort to find the factors causing acute postoperative infection. Culture of the cerebrospinal fluid (CSF) samples during the operation was positive in 33 cases. These cases were excluded from the series. Ninety infections were observed in the remaining 1141 operations, an overall rate of 7.9%. Most of these infections were meningitis (56 cases). Staphylococcus epidermidis was the bacterium most frequent identified (44%). Statistically significant relationships were found between shunt infection and the following factors: 1) age: infection was 2.6 times as frequent before 6 months than after 1 year of age (p = 0.03); 2) poor condition of the skin; 3) presence of intercurrent seats of infection at the time of surgery; 4) type of operation: the rate of infection was 8.4% in primary shunt insertions, 5% in shunt revisions, and 17.5% in reinsertions following shunt removal for infection (p = 0.0001); 5) end of the shunt requiring revision: an infection rate of 7.7% followed revision of the ventricular catheter alone, and 2.6% followed revision of the other end alone (p = 0.012); and 6) postoperative wound dehiscence or scalp necrosis. The surgical team involved was poorly correlated with the rate of infection (p = 0.12). No statistically significant relationships have been found between infection and 1) etiology of hydrocephalus; 2) sex; 3) recent neurosurgical operation before the shunt procedure; 4) preoperative presence of an external drainage tube or CSF fistula; 5) lumbar or ventricular taps, or ventriculography; 6) number of previous operations performed on the shunt; 7) time (month and year) of operation; or 8) sugar level and cell count in the CSF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Infections of Cerebrospinal Fluid Shunts: Epidemiology, Clinical Manifestations, and Therapy
Schoenbaum, S. C., Gardner, P., & Shillito, J. (1975) · Journal of Infectious Diseases · doi:10.1093/infdis/131.5.543 · Cited by 570
CHARNLEY, J. (1972) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-197209000-00020 · Cited by 432
Cited by
Tong, S. Y. C., Davis, J. S., Eichenberger, E., Holland, T. L., & Fowler, V. G. (2015) · Clinical Microbiology Reviews · doi:10.1128/cmr.00134-14 · Cited by 5,192
Tunkel, A. R., Hasbun, R., Bhimraj, A., Byers, K., Kaplan, S. L., Scheld, W. M., van de Beek, D., Bleck, T. P., Garton, H. J. L., & Zunt, J. R. (2017) · Clinical Infectious Diseases · doi:10.1093/cid/ciw861 · Cited by 1,067
Cerebrospinal fluid shunt infection: a prospective study of risk factors
Kulkarni, A. V., Drake, J. M., & Lamberti-Pasculli, M. (2001) · Journal of Neurosurgery · doi:10.3171/jns.2001.94.2.0195 · Cited by 367
Prevention and Management of Intrathecal Drug Delivery and Spinal Cord Stimulation System Infections
Follett, K. A., Boortz-Marx, R. L., Drake, J. M., DuPen, S., Schneider, S. J., Turner, M. S., & Coffey, R. J. (2004) · Anesthesiology · doi:10.1097/00000542-200406000-00034 · Cited by 232
“Postoperative CSF leakage(26) increased the risk of infection in some series but not in others.(14,33) Analysis of the responsible surgeon’s skill or experience and the duration of the implant operation, factors which may be interrelated, were significant in some studies(13,23,24,39) but not in others.”
BackgroundCerebrospinal fluid shunt infection: risk factors and long-term follow-up
Vinchon, M., & Dhellemmes, P. (2006) · Child's Nervous System · doi:10.1007/s00381-005-0037-8 · Cited by 218
“Several risk factors have been identified, in particular the age at shunt insertion, the experience of the neurosurgeon [3, 11, 17 ], and the cause of hydrocephalus [10, 13]; however, not all authors agree on the importance of these different variables [3, 8]. In addition, few long-term studies have been published; su…”
Pathobiology of Infection in Prosthetic Devices
Dougherty, S. H. (1988) · Clinical Infectious Diseases · doi:10.1093/clinids/10.6.1102 · Cited by 193
“Similarly, infections involving pacemaker pockets [125], intraocular lenses [126], the subcutaneous components of cerebrospinal fluid shunts [127-129], and other orthopedic devices [130-133] are usually caused by staphylococcal skin organisms and may result from spread of a superficial wound infection.”
Background
Metadata
- Authors
- Renier, D., Lacombe, J., Pierre-Kahn, A., Sainte-Rose, C., & Hirsch, J.-F.
- Venue
- Journal of Neurosurgery
- Published
- 1984-12
- Volume
- 61
- Issue
- 6
- Pages
- 1072-1078
- ISSN
- 0022-3085 (ISSN-L)
- OpenAlex
- W2097368345
- Cited by
- 212
- References
- 2
- FWCI
- 1.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.