Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 262

The DOI matches its Crossref record.

Time course of blood velocity changes related to vasospasm in the circle of Willis measured by transcranial Doppler ultrasound

Harders, Albrecht G., Gilsbach, Joachim M.·1987·Journal of Neurosurgery

Abstract

✓ Fifty patients with ruptured aneurysms were operated on within 72 hours after the first subarachnoid hemorrhage (SAH). To prevent symptomatic vasospasm, the patients were given the calcium channel blocker, nimodipine, intravenously (2 mg/hr) for 14 days and orally (60 mg four times daily) for another 7 days. At short intervals (at least every 3rd day) the blood flow velocity in the different segments of the circle of Willis was measured with a noninvasive transcranial Doppler ultrasonography method. Within the first 72 hours after SAH, the velocity was normal in the large branches of the circle of Willis and angiography revealed no signs of vasospasm. The Doppler frequency changes that relate to blood flow accelerated between Days 3 and 10, and maximum blood flow velocities were recorded between Days 11 and 20, with normalization occurring within the following 4 weeks. The changes showed a significant relationship to the source of SAH, the side of the operative approach, and the method of nimodipine administration. A comparison between the angiographically proven diameter of spastic arteries and the Doppler-measured blood flow velocity showed an inverse relationship in flow of the middle cerebral artery and the internal carotid artery that was statistically highly significant (p < 0.001) while this correlation was only slightly significant in the A 1 segment of the anterior cerebral artery (p = 0.054). Seven patients (14%) developed delayed ischemic deficits (DID's), which were all functionally reversible. One patient (2%) died as a result of decompensated vasospasm. Based on the information provided by Doppler measurement of the individual blood flow velocity changes due to vasospasm, preventive hypertensive treatment was introduced to improve the perfusion pressure while patients were still in an asymptomatic stage. Among the last 40 patients who were treated according to this regimen, reversible DID's were observed in only three patients (7.5%) and postoperative angiography to detect vasospasm was not necessary.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3171/jns.1987.66.5.0718

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 262

Metadata

Authors
Harders, A. G., & Gilsbach, J. M.
Venue
Journal of Neurosurgery
Published
1987-05
Volume
66
Issue
5
Pages
718-728
ISSN
0022-3085 (ISSN-L)
OpenAlex
W2138018179
Cited by
262
References
0
FWCI
12.41
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Time course of blood velocity changes related to vasospasm in the circle of Willis measured by transcranial Doppler ultrasound. https://app.cochat.ai/papers/10.3171/jns.1987.66.5.0718
The paper
Harders, A. G., & Gilsbach, J. M. (1987). Time course of blood velocity changes related to vasospasm in the circle of Willis measured by transcranial Doppler ultrasound. Journal of Neurosurgery. https://doi.org/10.3171/jns.1987.66.5.0718

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.