The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Monitoring of autoregulation using laser Doppler flowmetry in patients with head injury
Abstract
✓ The authors studied 31 comatose head-injured patients to assess the clinical usefulness of laser Doppler flowmetry (LDF) in continuous autoregulation monitoring. The LDF probes were placed on the surface of the cerebral cortex. Data on LDF, intracranial pressure (ICP), and arterial blood pressure (ABP) were recorded and continuously entered into a computer. The data were broken down into multiple segments of 15 minutes' duration (epochs). Epochs showing rapid change in cerebral perfusion pressure (CPP), change in CPP of less than 10 mm Hg, LDF values of less than five arbitrary units, and loss of ABP/ICP waveform were excluded from further analysis. A linear relationship between LDF and CPP in individual epochs was used as an indicator of loss of autoregulation. The relationship between LDF and CPP changed with time, indicating improvement or deterioration in autoregulation. Longitudinal analysis of all the epochs measured in a patient revealed three patterns of progress: 1) intact autoregulation; 2) transient loss; and 3) persistent loss of autoregulation. All five patients with intact autoregulation had a good outcome. Ten patients experienced transient loss of autoregulation; of these four had a good outcome, five were moderately disabled, and one was severely disabled. Transient impairment of autoregulation did not always indicate poor outcome, provided the impaired autoregulation responded to treatment. In 11 patients who had persistent loss of autoregulation, nine died and two were severely disabled. In five cases the LDF probe lost contact with the cerebral cortex and no useful information was obtained. Real-time measurement of autoregulation using LDF and CPP monitors was achieved and the findings were related to outcome in these patients.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“SIS is thought to result from abrupt post-traumatic loss of cerebral blood flow autoregulation and catecholamine release that create a rapid increase in intracranial blood volume and catastrophic cerebral edema [32, 105].”
From The neuropathology of sport (2014) · cites this paper as [105]
Citations
Cites
Cerebral autoregulation dynamics in humans.
Aaslid, R., Lindegaard, K.-F., Sorteberg, W., & NORNES, H. (1989) · Stroke · doi:10.1161/01.str.20.1.45 · Cited by 1,630
Impact of ICP instability and hypotension on outcome in patients with severe head trauma
Marmarou, A., Anderson, R. L., Ward, J. D., Choi, S. C., Young, H. F., Eisenberg, H. M., Foulkes, M. A., Marshall, L. F., & Jane, J. A. (1991) · Journal of neurosurgery · doi:10.3171/sup.1991.75.1s.0s59 · Cited by 815
Initial CT findings in 753 patients with severe head injury
Eisenberg, H. M., Gary, H. E., Aldrich, E. F., Saydjari, C., Turner, B., Foulkes, M. A., Jane, J. A., Marmarou, A., Marshall, L. F., & Young, H. F. (1990) · Journal of neurosurgery · doi:10.3171/jns.1990.73.5.0688 · Cited by 609
Dirnagl, U., Kaplan, B. E., Jacewicz, M., & Pulsinelli, W. A. (1989) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1989.84 · Cited by 475
Extracranial complications of severe head injury
Piek, J., Chesnut, R. M., Marshall, L. F., van Berkum-Clark, M., Klauber, M. R., Blunt, B. A., Eisenberg, H. M., Jane, J. A., Marmarou, A., & Foulkes, M. A. (1992) · Journal of neurosurgery · doi:10.3171/jns.1992.77.6.0901 · Cited by 323
Cerebral Blood Flow, Cerebral Blood Volume, and Cerebrovascular Reactivity after Severe Head Injury
Bouma, G. J., & Muizelaar, J. P. (1992) · Journal of Neurotrauma · doi:10.1177/089771519200901s33 · Cited by 234
Laser-Doppler assessment of brain microcirculation: effect of systemic alterations
Haberl, R. L., Heizer, M. L., Marmarou, A., & Ellis, E. F. (1989) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1989.256.4.h1247 · Cited by 220
Czosnyka, M., Richards, H. K., Whitehouse, H., & Pickard, J. D. (1996) · Journal of neurosurgery · doi:10.3171/jns.1996.84.1.0079 · Cited by 205
Skarphedinsson, J. O., Hårding, H., & Thorén, P. (1988) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1988.tb08469.x · Cited by 164
Evaluation of an infrared laser-Doppler blood flowmeter
Shepherd, A. P., Riedel, G. L., Kiel, J. W., Haumschild, D. J., & Maxwell, L. C. (1987) · American Journal of Physiology-Gastrointestinal and Liver Physiology · doi:10.1152/ajpgi.1987.252.6.g832 · Cited by 120
Research works printed but not linked: 8
- Bouma GJ, 1992, J Neurotrauma, 9, S333
- DiResta GR, 1987, Am J Physiol, 253, G573
- Fabricius M, 1994, Am J Physiol, 266, H1457
- Goadsby PJ, 1991, Am J Physiol, 260, R255
- Haberl RL, 1989, Am J Physiol, 256, H1247
- Lindsberg PJ, 1989, Am J Physiol, 257, H674
- Shepherd AP, 1987, Am J Physiol, 252, G832
- Talman WT, 1991, Am J Physiol, 261, H707
Cited by
Sorted by citations
Pathophysiology of traumatic brain injury
Werner, C., & Engelhard, K. (2007) · British Journal of Anaesthesia · doi:10.1093/bja/aem131 · Cited by 1,712
The neuropathology of traumatic brain injury
McKee, A. C., & Daneshvar, D. H. (2015) · Handbook of clinical neurology · doi:10.1016/b978-0-444-52892-6.00004-0 · Cited by 899
Assessment of cerebral pressure autoregulation in humans - a review of measurement methods
Panerai, R. B. (1998) · Physiological Measurement · doi:10.1088/0967-3334/19/3/001 · Cited by 506
Recent Advances in Pathophysiology of Traumatic Brain Injury
Kaur, P., & Sharma, S. (2017) · Current Neuropharmacology · doi:10.2174/1570159x15666170613083606 · Cited by 471
McKee, A. C., Daneshvar, D. H., Alvarez, V. E., & Stein, T. D. (2014) · Acta Neuropathologica · doi:10.1007/s00401-013-1230-6 · Cited by 422
Metadata
- Authors
- Lam, J. M. K., Hsiang, J. N. K., & Poon, W. S.
- Affiliations
- Chinese University of Hong Kong (HK)
- ORCID
- Poon, Wai S.
- Venue
- Journal of Neurosurgery
- Published
- 1997-03
- Volume
- 86
- Issue
- 3
- Pages
- 438-445
- ISSN
- 0022-3085 (ISSN-L)
- OpenAlex
- W2062965541
- Cited by
- 150
- References
- 29
- Citations by year
- 2025: 3 · 2024: 5 · 2023: 2 · 2022: 2 · 2021: 3 · 2020: 4 · 2019: 2 · 2018: 5 · 2017: 14 · 2016: 5 · 2015: 7 · 2014: 4 · 2013: 6 · 2012: 7
- FWCI
- 4.52
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of neurosurgery (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Clinical Neurology › Traumatic Brain Injury and Neurovascular Disturbances
- Health Sciences › Medicine › Clinical Neurology › Traumatic Brain Injury Research
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Keywords
- cerebral autoregulation, laser Doppler flowmetry, traumatic brain injury, coma, cerebral perfusion pressure, intracranial pressure, arterial blood pressure, outcome prediction, real-time monitoring
- MeSH terms
- Adult, Aged, Blood Pressure, Brain Injuries, Cerebral Cortex, Cerebral Hemorrhage, Cerebrovascular Circulation, Child, Child, Preschool, Coma, Female, Follow-Up Studies, Disabled Persons, Persons with Disabilities, Homeostasis, Humans, Intracranial Pressure, Jugular Veins, Longitudinal Studies, Male, Middle Aged, Monitoring, Physiologic, Oxygen, Signal Processing, Computer-Assisted, Survival Rate, Treatment Outcome, Laser-Doppler Flowmetry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review