CoChat
Cited by 161

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Accuracy of true frameless stereotaxy: in vivo measurement and laboratory phantom studies: Technical note

Dorward, Neil L., Alberti, Olaf, Palmer, James D., Kitchen, Neil D., Thomas, David G. T. · 1999 · Journal of Neurosurgery

Abstract

✓ The authors present the results of accuracy measurements, obtained in both laboratory phantom studies and an in vivo assessment, for a technique of frameless stereotaxy. An instrument holder was developed to facilitate stereotactic guidance and enable introduction of frameless methods to traditional frame-based procedures. The accuracy of frameless stereotaxy was assessed for images acquired using 0.5-tesla or 1.5-tesla magnetic resonance (MR) imaging or 2-mm axial, 3-mm axial, or 3-mm helical computerized tomography (CT) scanning. A clinical series is reported in which biopsy samples were obtained using a frameless stereotactic procedure, and the accuracy of these procedures was assessed using postoperative MR images and image fusion. The overall mean error of phantom frameless stereotaxy was found to be 1.3 mm (standard deviation [SD] 0.6 mm). The mean error for CT-directed frameless stereotaxy was 1.1 mm (SD 0.5 mm) and that for MR image—directed procedures was 1.4 mm (SD 0.7 mm). The CT-guided frameless stereotaxy was significantly more accurate than MR image—directed stereotaxy (p = 0.0001). In addition, 2-mm axial CT-guided stereotaxy was significantly more accurate than 3-mm axial CT-guided stereotaxy (p = 0.025). In the clinical series of 21 frameless stereotactically obtained biopsies, all specimens yielded the appropriate diagnosis and no complications ensued. Early postoperative MR images were obtained in 16 of these cases and displacement of the biopsy site from the intraoperative target was determined by fusion of pre- and postoperative image data sets. The mean in vivo linear error of frameless stereotactic biopsy sampling was 2.3 mm (SD 1.9 mm). The mean in vivo Euclidean error was 4.8 mm (SD 2 mm). The implications of these accuracy measurements and of error in stereotaxy are discussed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3171/jns.1999.90.1.0160

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 161

Metadata

Authors
Dorward, N. L., Alberti, O., Palmer, J. D., Kitchen, N. D., & Thomas, D. G. T.
Venue
Journal of Neurosurgery
Published
1999-01
Volume
90
Issue
1
Pages
160-168
ISSN
0022-3085 (ISSN-L)
OpenAlex
W2056664373
Cited by
161
References
1
FWCI
6.42
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.