Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 186

The DOI matches its Crossref record.

Seven years of clinical experience with the programmable Codman Hakim valve: a retrospective study of 583 patients

Zemack, Göran, Romner, Bertil·2000·Journal of Neurosurgery

Abstract

Object. The goal of this study was to assess the value of the Codman Hakim programmable valve to settings in the range of 30 to 200 mm H 2 O. This valve can be adjusted noninvasively for cerebrospinal fluid (CSF) drainage. Methods. The authors conducted a single-center retrospective study of 583 patients (421 adults and 162 children) suffering from hydrocephalus of various causes (379 patients), normal-pressure hydrocephalus (174 patients), arachnoid cyst (14 patients), and pseudotumor cerebri (16 patients). In all cases a Codman Hakim programmable valve was implanted; in 82.8% of cases it was included during the patient's first shunt implantation. In 42.4% of the cases valve pressure adjustment was required at least once (mean number of adjustments 1.2, maximum 23). The patients' clinical status improved after 64.6% of pressure adjustments. Accidental resetting of opening pressure, other than that caused by magnetic resonance (MR) imaging, was uncommon. Because MR imaging caused resetting in 26.8% of cases in which it was used, it was deemed mandatory to obtain an x-ray film after MR imaging. Valve malfunction, blockage, or adjustment difficulties occurred in 2% of valves implanted, and nontraumatic subdural fluid collections were demonstrated in 5.1% of patients (13 of whom were treated by valve pressure adjustment alone). Five-year shunt survival was 53.1% for first-time shunt implantations. The shunt infection rate was 8.5% of valve implantations. Catheter-related complications and shunt-related infections were the main reasons for surgical revision and the major cause of shunt failure. At follow-up review, 97% of children and 90% of adults had improved. Conclusions. Because one cannot know in advance which case will turn out to be complicated, the authors' preference is to use the Codman Hakim programmable valve for all conditions in which CSF should be drained.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3171/jns.2000.92.6.0941

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 186

Metadata

Authors
Zemack, G., & Romner, B.
Venue
Journal of Neurosurgery
Published
2000-06
Volume
92
Issue
6
Pages
941-948
ISSN
0022-3085 (ISSN-L)
OpenAlex
W2040006793
Cited by
186
References
0
FWCI
2.94
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Seven years of clinical experience with the programmable Codman Hakim valve: a retrospective study of 583 patients. https://app.cochat.ai/papers/10.3171/jns.2000.92.6.0941
The paper
Zemack, G., & Romner, B. (2000). Seven years of clinical experience with the programmable Codman Hakim valve: a retrospective study of 583 patients. Journal of Neurosurgery. https://doi.org/10.3171/jns.2000.92.6.0941

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.