Analysis of brain biocompatibility of drug-releasing biodegradable microspheres by scanning and transmission electron microscopy
The DOI matches its Crossref record.
Abstract
Object. Stereotactically guided implantation of biodegradable microspheres is a promising strategy for delivery of neurotrophic factors in a precise and spatially defined brain area. The goal in this study was to show the biocompatibility of poly(D,L,lactide-co-glycolide) microspheres with brain tissue at the ultrastructural level and to analyze the three-dimensional (3D) ultrastructure after intrastriatal implantation of these microparticles. Methods. Scanning and transmission electron microscopy were used to study the microspheres and their environment after implantation in an inert material (gelatin) and in the rat striatum. Observations were made at different time periods, ranging from 24 hours to 2 months postimplantation. Conclusions. The progressive degradation of the microspheres, with vacuolization, deformation, and shrinkage, was well visualized. This degradation was identical in microspheres implanted in the inert material and in the rat brain tissue, independent of the presence of macrophages. The studies preformed in the striatum permitted the authors to demonstrate the structural integrity of axons in contact with microspheres, confirming the biocompatibility of the polymer. Furthermore, scanning electron microscopy showed the preservation of the 3D ultrastructure of the striatum around the microparticles. These microparticles, which can be stereotactically implanted in functional areas of the brain and can release neurotrophic factors, could represent, for some indications, an alternative to gene therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biocompatibility of implantable synthetic polymeric drug carriers: focus on brain biocompatibility
Fournier, E., Passirani, C., Montero-Menei, C. N., & Benoit, J. P. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00161-3 · Cited by 353
Self-citationCholeris, E., Little, S. R., Mong, J. A., Puram, S. V., Langer, R., & Pfaff, D. W. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0700670104 · Cited by 183
Effective GDNF brain delivery using microspheres—A promising strategy for Parkinson's disease
Garbayo, E., Montero-Menei, C. N., Ansorena, E., Lanciego, J. L., Aymerich, M. S., & Blanco-Prieto, M. J. (2009) · Journal of Controlled Release · doi:10.1016/j.jconrel.2008.12.010 · Cited by 150
Self-citationJollivet, C., Aubert-Pouessel, A., Clavreul, A., Venier-Julienne, M.-C., Montero-Menei, C. N., Benoit, J.-P., & Menei, P. (2004) · Neuroscience Letters · doi:10.1016/j.neulet.2003.11.051 · Cited by 43
Self-citationBiodegradable microparticles for strictly regulating the release of neurotrophic factors
Gujral, C., Minagawa, Y., Fujimoto, K., Kitano, H., & Nakaji-Hirabayashi, T. (2013) · Journal of Controlled Release · doi:10.1016/j.jconrel.2013.03.031 · Cited by 21
Metadata
- Authors
- Veziers, J., Lesourd, M., Jollivet, C., Montero-Menei, C., Benoit, J.-P., & Menei, P.
- Venue
- Journal of Neurosurgery
- Published
- 2001-09
- Volume
- 95
- Issue
- 3
- Pages
- 489-494
- ISSN
- 0022-3085 (ISSN-L)
- OpenAlex
- W1986486558
- Cited by
- 44
- References
- 0
- FWCI
- 4.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Analysis of brain biocompatibility of drug-releasing biodegradable microspheres by scanning and transmission electron microscopy. https://app.cochat.ai/papers/10.3171/jns.2001.95.3.0489
- The paper
- Veziers, J., Lesourd, M., Jollivet, C., Montero-Menei, C., Benoit, J.-P., & Menei, P. (2001). Analysis of brain biocompatibility of drug-releasing biodegradable microspheres by scanning and transmission electron microscopy. Journal of Neurosurgery. https://doi.org/10.3171/jns.2001.95.3.0489
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.