The DOI matches its Crossref record.
Buenos Aires experience with the Neuroform self-expanding stent for the treatment of intracranial aneurysms
Abstract
Object. The authors report their experience with the use of the Neuroform Microdelivery System for intravascular reconstruction. They assess the technical feasibility of the system, the efficacy of the combined application of stent and detachable coils, and the follow-up findings. Methods. Fifty patients found to harbor a complex wide-necked intracranial aneurysm were selected for the study. Different strategies were chosen and the performance and technical success of the device were evaluated. Stent placement was recorded as optimal or suboptimal with respect to the stent position. Clinical and angiographic follow-up examinations were obtained. Forty-six patients with 48 intracranial aneurysms were treated, leading to a technical success rate of 92%. Forty-two lesions were located in the anterior circulation. In every case the dome/neck ratio was less than 2 and the mean aneurysm size in these patients was 8.8 mm. The most frequent clinical presentation was subarachnoid hemorrhage in 48% of cases. Stent placement was optimal in 81.2% of cases and suboptimal in 18.8%. In 31% of cases, the investigators encountered difficulties in placing the Neuroform stent. Clinical follow up was recorded in all patients and angiographic follow up was obtained in 63%. There were no cases of repeated hemorrhage. In a single case in which only the stent was implanted progressive thrombosis was identified during the follow-up period. The procedure-related morbidity and mortality rates were 8.6 and 2.1%, respectively. Conclusions. On the basis of the results, the authors conclude that the Neuroform self-expanding stent is a flexible and useful device that can be readily and safely maneuvered through tortuous intracranial vessels, enabling the endovascular treatment of complex wide-necked aneurysms. Early in the authors' experience, stent delivery presented difficulties; however, a second generation of devices has resolved this limitation. Although the early results are promising, the long-term benefit of this technique has to be proved by angiographic and clinical follow-up examinations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Brisman, J. L., Song, J. K., & Newell, D. W. (2006) · New England Journal of Medicine · doi:10.1056/nejmra052760 · Cited by 896
Piotin, M., Blanc, R., Spelle, L., Mounayer, C., Piantino, R., Schmidt, P. J., & Moret, J. (2010) · Stroke · doi:10.1161/strokeaha.109.558114 · Cited by 644
Cebral, J. R., Mut, F., Raschi, M., Scrivano, E., Ceratto, R., Lylyk, P., & Putman, C. M. (2011) · American Journal of Neuroradiology · doi:10.3174/ajnr.a2398 · Cited by 390
Self-citationSaatci, I., Yavuz, K., Ozer, C., Geyik, S., & Cekirge, H. S. (2012) · American Journal of Neuroradiology · doi:10.3174/ajnr.a3246 · Cited by 368
Endovascular Management of Intracranial Aneurysms: Current Experience and Future Advances
Koebbe, C. J., Veznedaroglu, E., Jabbour, P., & Rosenwasser, R. H. (2006) · Neurosurgery · doi:10.1227/01.neu.0000237512.10529.58 · Cited by 103
Metadata
- Authors
- Lylyk, P., Ferrario, A., Pabón, B., Miranda, C., & Doroszuk, G.
- Venue
- Journal of Neurosurgery
- Published
- 2005-02
- Volume
- 102
- Issue
- 2
- Pages
- 235-241
- ISSN
- 0022-3085 (ISSN-L)
- OpenAlex
- W2132627906
- Cited by
- 211
- References
- 0
- FWCI
- 14.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Buenos Aires experience with the Neuroform self-expanding stent for the treatment of intracranial aneurysms. https://app.cochat.ai/papers/10.3171/jns.2005.102.2.0235
- The paper
- Lylyk, P., Ferrario, A., Pabón, B., Miranda, C., & Doroszuk, G. (2005). Buenos Aires experience with the Neuroform self-expanding stent for the treatment of intracranial aneurysms. Journal of Neurosurgery. https://doi.org/10.3171/jns.2005.102.2.0235
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.