Cervical nerve root avulsion in brachial plexus injuries: magnetic resonance imaging classification and comparison with myelography and computerized tomography myelography
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Object. The authors describe a new magnetic resonance (MR) imaging technique to demonstrate the status of the cervical nerve roots involved in brachial plexus injury. They discuss the accuracy and reproducibility of a MR imaging—derived classification for diagnosis of nerve root avulsion compared with those of myelography combined with computerized tomography (CT) myelography. Methods. The overlapping coronal—oblique slice MR imaging procedure was performed in 35 patients with traumatic brachial plexus injury and 10 healthy individuals. The results were retrospectively evaluated and classified into four major categories (normal rootlet, rootlet injuries, avulsion, and meningocele) after confirming the diagnosis by surgical exploration with or without spinal evoked potential (EP) measurements and by referring to myelography and CT myelography findings. The reliability and reproducibility of the MR imaging—based classification was prospectively assessed by eight independent observers, and its diagnostic accuracy was compared with that of traditional myelography/CT myelography classification, correlated with surgical and spinal EP findings in another 50 cervical roots in 10 patients with traumatic brachial plexus injury. Conclusions. In the retrospective study in which MR imaging and myelography/CT myelography findings involving 175 cervical roots in 35 patients were compared, the sensitivity of detection of the cervical nerve root avulsion was the same (92.9%) with both modalities. In the prospective study, interobserver reliability and intraobserver reproducibility showed that there was no statistically significant difference between MR imaging and myelography/CT myelography and that their accuracy for detecting cervical root avulsion was the same as that in the retrospective study. The overlapping coronal—oblique slice MR imaging technique is a reliable and reproducible method for detecting nerve root avulsion. The information provided by this modality enabled the authors to assess the roots of the brachial plexus and provided valuable data for helping to decide whether to proceed with exploration, nerve repair, primary reconstruction, or other imaging modalities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
Cited by
Severe chronic morbidity following childbirth
Leung, T. Y., & Chung, T. K. H. (2009) · Best Practice & Research Clinical Obstetrics & Gynaecology · doi:10.1016/j.bpobgyn.2009.01.002 · Cited by 15
Metadata
- Authors
- Doi, K., Otsuka, K., Okamoto, Y., Fujii, H., Hattori, Y., & Baliarsing, A. S.
- Venue
- Journal of Neurosurgery: Spine
- Published
- 2002-04
- Volume
- 96
- Issue
- 3
- Pages
- 277-284
- ISSN
- 1547-5646 (ISSN-L)
- 1547-5654
- OpenAlex
- W2145340948
- Cited by
- 172
- References
- 1
- FWCI
- 6.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.