The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Percutaneous vertebroplasty and kyphoplasty for painful vertebral body fractures in cancer patients
Abstract
Object. The current North American experience with minimally invasive vertebro- and kyphoplasty is largely limited to the treatment of benign osteoporotic compression fractures. The objective of this study was to assess the safety and efficacy of these procedures for painful vertebral body (VB) fractures in cancer patients. Methods. The authors reviewed a consecutive group of cancer patients (21 with myeloma and 35 with other primary malignancies) undergoing vertebro- and kyphoplasty at their institution. Ninety-seven (65 vertebro- and 32 kyphoplasty) procedures were performed in 56 patients during 58 treatment sessions. The mean patient age was 62 years (± 13 years [standard deviation]) and the median duration of symptoms was 3.2 months. All patients suffered intractable spinal pain secondary to VB fractures. Patients noted marked or complete pain relief after 49 procedures (84%), and no change after five procedures (9%); early postoperative Visual Analog Scale (VAS) pain scores were unavailable in four patients (7%). No patient was worse after treatment. Reductions in VAS pain scores remained significant up to 1 year (p = 0.02, Wilcoxon signed-rank test). Analgesic consumption was reduced at 1 month (p = 0.03, Wilcoxon signed-rank test). Median follow-up length was 4.5 months (range 1 day–19.7 months). Asymptomatic cement leakage occurred during vertebroplasty at six (9.2%) of 65 levels; no cement extravasation was seen during kyphoplasty. There were no deaths or complications related to the procedures. The mean percentage of restored VB height by kyphoplasty was 42 ± 21%. Conclusions. Percutaneous vertebro- and kyphoplasty provided significant pain relief in a high percentage of patients, and this appeared durable over time. The absence of cement leakage—related complications may reflect the use of 1) high-viscosity cement; 2) kyphoplasty in selected cases; and 3) relatively small 3volume injection. Precise indications for these techniques are evolving; however, they are safe and feasible in well-selected patients with refractory spinal pain due to myeloma bone disease or metastases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Graphic representation of pain
Scott, J., & Huskisson, E. C. (1976) · Pain · doi:10.1016/0304-3959(76)90113-5 · Cited by 2,706
Frankel, H. L., Hancock, D. O., Hyslop, G., Melzak, J., Michaelis, L. S., Ungar, G. H., Vernon, J. D. S., & Walsh, J. J. (1969) · Spinal Cord · doi:10.1038/sc.1969.30 · Cited by 2,273
Garfin, S. R., Yuan, H. A., & Reiley, M. A. (2001) · Spine · doi:10.1097/00007632-200107150-00002 · Cited by 1,087
Lieberman, I. H., Dudeney, S., Reinhardt, M.-K., & Bell, G. (2001) · Spine · doi:10.1097/00007632-200107150-00026 · Cited by 999
Cited by
Multiple Myeloma: Diagnosis and Treatment
Rajkumar, S. V., & Kumar, S. (2016) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2015.11.007 · Cited by 812
“Vertebroplasty (injection of methylmethacrylate into a collapsed vertebral body) or kyphoplasty (introduction of an inflatable bone tamp into the vertebral body and after inflation the injection of methylmethacrylate into the cavity) can be used to decrease pain from vertebral fractures.(124) Some patients with”
BackgroundVertebroplasty and Kyphoplasty: A Systematic Review of 69 Clinical Studies
Hulme, P. A., Krebs, J., Ferguson, S. J., & Berlemann, U. (2006) · Spine · doi:10.1097/01.brs.0000229254.89952.6b · Cited by 754
Paice, J. A., Portenoy, R., Lacchetti, C., Campbell, T., Cheville, A., Citron, M., Constine, L. S., Cooper, A., Glare, P., Keefe, F., et al. (2016) · Journal of Clinical Oncology · doi:10.1200/jco.2016.68.5206 · Cited by 599
Fourney, D. R., Frangou, E. M., Ryken, T. C., DiPaola, C. P., Shaffrey, C. I., Berven, S. H., Bilsky, M. H., Harrop, J. S., Fehlings, M. G., Boriani, S., et al. (2011) · Journal of Clinical Oncology · doi:10.1200/jco.2010.34.3897 · Cited by 551
Self-citationBarlogie, B., Shaughnessy, J., Tricot, G., Jacobson, J., Zangari, M., Anaissie, E., Walker, R., & Crowley, J. (2004) · Blood · doi:10.1182/blood-2003-04-1045 · Cited by 464
Metadata
- Authors
- Fourney, D. R., Schomer, D. F., Nader, R., Chlan-Fourney, J., Suki, D., Ahrar, K., Rhines, L. D., & Gokaslan, Z. L.
- Venue
- Journal of Neurosurgery: Spine
- Published
- 2003-01
- Volume
- 98
- Issue
- 1
- Pages
- 21-30
- ISSN
- 1547-5646 (ISSN-L)
- 1547-5654
- OpenAlex
- W3022714424
- Cited by
- 611
- References
- 4
- FWCI
- 41.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.