Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 234

The DOI matches its Crossref record.

Detection of Aneurysms by 64-Section Multidetector CT Angiography in Patients Acutely Suspected of Having an Intracranial Aneurysm and Comparison with Digital Subtraction and 3D Rotational Angiography

Open access
McKinney, A.M., Palmer, C.S., Truwit, C.L., Karagulle, A., Teksam, M. · 2008 · American Journal of Neuroradiology

Abstract

BACKGROUND AND PURPOSE: Four-section multisection CT angiography (MSCTA) accurately detects aneurysms at or more than 4 mm but is less accurate for those less than 4 mm. Our purpose was to determine the accuracy of 64-section MSCTA (64MSCTA) in aneurysm detection versus combined digital subtraction angiography (DSA) and 3D rotational angiography (3DRA). MATERIALS AND METHODS: In a retrospective review of patients studied because of acute symptoms suspicious for arising from an intracranial aneurysm, 63 subjects were included who had undergone CT angiography (CTA). Of these, 36 underwent catheter DSA; all but 4 were also studied with 3DRA. The most common indication was subarachnoid hemorrhage (SAH; n = 43). Two neuroradiologists independently reviewed each CTA, DSA, and 3DRA. RESULTS: A total of 41 aneurysms were found in 28 patients. The mean size was 6.09 mm on DSA/3DRA and 5.98 mm on 64MSCTA. kappa was excellent (0.97) between the aneurysm size on 64MSCTA and DSA/3DRA. Ultimately, 37 aneurysms were detected by DSA/3DRA in 25 of the 36 patients who underwent conventional angiography. The reviewers noted four 1- to 1.5-mm sessile outpouchings only on 3DRA; none were considered a source of SAH. One 64MSCTA was false positive, whereas one 2-mm aneurysm was missed by CTA. The sensitivity of CTA for aneurysms less than 4 mm was 92.3%, whereas it was 100% for those 4-10 mm and more than 10 mm, excluding the indeterminate, sessile lesions. CONCLUSIONS: In comparison with the available literature, 64MSCTA may have improved the detection of less than 4-mm aneurysms compared with 4- or 16-section CTA. However, the combination of DSA with 3DRA is currently the most sensitive technique to detect untreated aneurysms and should be considered in suspicious cases of SAH where the aneurysm is not depicted by 64MSCTA, because 64MSCTA may occasionally miss aneurysms less than 3-4 mm size.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3174/ajnr.a0848

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 234

Metadata

Authors
McKinney, A. M., Palmer, C. S., Truwit, C. L., Karagulle, A., & Teksam, M.
Venue
American Journal of Neuroradiology
Published
2007-12-07
Volume
29
Issue
3
Pages
594-602
ISSN
  • 0195-6108 (ISSN-L)
  • 1936-959X
OpenAlex
W2129177890
Cited by
234
References
0
FWCI
7.78
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Detection of Aneurysms by 64-Section Multidetector CT Angiography in Patients Acutely Suspected of Having an Intracranial Aneurysm and Comparison with Digital Subtraction and 3D Rotational Angiography. https://app.cochat.ai/papers/10.3174/ajnr.a0848
The paper
McKinney, A. M., Palmer, C. S., Truwit, C. L., Karagulle, A., & Teksam, M. (2008). Detection of Aneurysms by 64-Section Multidetector CT Angiography in Patients Acutely Suspected of Having an Intracranial Aneurysm and Comparison with Digital Subtraction and 3D Rotational Angiography. American Journal of Neuroradiology. https://doi.org/10.3174/ajnr.a0848

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.