CoChat

An MRI Rating Scale for Amyloid-Related Imaging Abnormalities with Edema or Effusion

Open access
Barkhof, F., Daams, M., Scheltens, P., Brashear, H.R., Arrighi, H.M., Bechten, A., Morris, K., McGovern, M., Wattjes, M.P. · 2013 · American Journal of Neuroradiology
Cited by 60

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

BACKGROUND AND PURPOSE: Immune therapy against amyloid-β appears to be a promising target in Alzheimer disease. However, a dose-related risk for ARIA on FLAIR images thought to represent parenchymal vasogenic edema or sulcal effusion (termed "ARIA-E"), has been observed in clinical trials. To assess the intensity of ARIA-E presentation, an MR imaging scale that is both reproducible and easily implemented would assist in monitoring and evaluating this adverse event. MATERIALS AND METHODS: On the basis of a review of existing cases from a phase II bapineuzumab study, a scale was constructed with a 6-point score for the 6 regions on each side of the brain (range, 0-60). Scores would be obtained for both parenchymal and sulcal hyperintensities and frequently co-occurring gyral swelling. Inter-rater reliability between 2 neuroradiologists was evaluated in 20 patients, 10 with known ARIA-E and 10 without, by using the intraclass correlation coefficient. RESULTS: The 2 raters had excellent agreement in the identification of ARIA-E cases. A high inter-rater agreement was observed for scores of parenchymal hyperintensity (ICC = 0.83; 95% CI, 48-96) and sulcal hyperintensity (ICC = 0.89; 95% CI, 63-97) and for the combined scores of the 2 ARIA-E findings (ICC = 0.89; 95% CI, 62-97). Gyral swelling scores were observed to have lower inter-rater agreement (ICC = 0.54; 95% CI, -0.06-0.86). CONCLUSIONS: The proposed rating scale provides a reliable and easily implemented instrument to grade ARIA-E imaging findings. We currently do not recommend including swelling.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3174/ajnr.a3475

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 60

Metadata

Authors
Barkhof, F., Daams, M., Scheltens, P., Brashear, H. R., Arrighi, H. M., Bechten, A., Morris, K., McGovern, M., & Wattjes, M. P.
Venue
American Journal of Neuroradiology
Published
2013-02-22
Volume
34
Issue
8
Pages
1550-1555
ISSN
  • 0195-6108 (ISSN-L)
  • 1936-959X
OpenAlex
W2153842052
Cited by
60
References
13
FWCI
1.43
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An MRI Rating Scale for Amyloid-Related Imaging Abnormalities with Edema or Effusion. https://app.cochat.ai/papers/10.3174/ajnr.a3475
The paper
Barkhof, F., Daams, M., Scheltens, P., Brashear, H. R., Arrighi, H. M., Bechten, A., Morris, K., McGovern, M., & Wattjes, M. P. (2013). An MRI Rating Scale for Amyloid-Related Imaging Abnormalities with Edema or Effusion. American Journal of Neuroradiology. https://doi.org/10.3174/ajnr.a3475

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.