CoChat

MR Imaging Features of Amyloid-Related Imaging Abnormalities

Open access
Barakos, J., Sperling, R., Salloway, S., Jack, C., Gass, A., Fiebach, J.B., Tampieri, D., Melançon, D., Miaux, Y., Rippon, G., Black, R., Lu, Y., Brashear, H.R., Arrighi, H.M., Morris, K.A., Grundman, M. · 2013 · American Journal of Neuroradiology
Cited by 118

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

BACKGROUND AND PURPOSE: AD is one of the few leading causes of death without a disease-modifying drug; however, hopeful agents are in various phases of development. MR imaging abnormalities, collectively referred to as amyloid-related imaging abnormalities, have been reported for several agents that target cerebral Aβ burden. ARIA includes ARIA-E, parenchymal or sulcal hyperintensities on FLAIR indicative of parenchymal edema or sulcal effusions, and ARIA-H, hypointense regions on gradient recalled-echo/T2* indicative of hemosiderin deposition. This report describes imaging characteristics of ARIA-E and ARIA-H identified during studies of bapineuzumab, a humanized monoclonal antibody against Aβ. MATERIALS AND METHODS: Two neuroradiologists with knowledge of imaging changes reflective of ARIA reviewed MR imaging scans from 210 bapineuzumab-treated patients derived from 3 phase 2 studies. Each central reader interpreted the studies independently, and discrepancies were resolved by consensus. The inter-reader κ was 0.76, with 94% agreement between neuroradiologists regarding the presence or absence of ARIA-E in individual patients. RESULTS: Thirty-six patients were identified with incident ARIA-E (17.1%, 36/210) and 26 with incident ARIA-H (12.4%, 26/210); of those with incident ARIA-H, 24 had incident microhemorrhages and 2 had incident large superficial hemosiderin deposits. CONCLUSIONS: In 49% of cases of ARIA-E, there was the associated appearance of ARIA-H. In treated patients without ARIA-E, the risk for incident blood products was 4%. This association between ARIA-E and ARIA-H may suggest a common pathophysiologic mechanism. Familiarity with ARIA should permit radiologists and clinicians to recognize and communicate ARIA findings more reliably for optimal patient management.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3174/ajnr.a3500

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 118

Metadata

Authors
Barakos, J., Sperling, R., Salloway, S., Jack, C., Gass, A., Fiebach, J. B., Tampieri, D., Melançon, D., Miaux, Y., Rippon, G., Black, R., Lu, Y., Brashear, H. R., Arrighi, H. M., Morris, K. A., & Grundman, M.
Venue
American Journal of Neuroradiology
Published
2013-04-11
Volume
34
Issue
10
Pages
1958-1965
ISSN
  • 0195-6108 (ISSN-L)
  • 1936-959X
OpenAlex
W2166411759
Cited by
118
References
10
FWCI
3.06
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: MR Imaging Features of Amyloid-Related Imaging Abnormalities. https://app.cochat.ai/papers/10.3174/ajnr.a3500
The paper
Barakos, J., Sperling, R., Salloway, S., Jack, C., Gass, A., Fiebach, J. B., Tampieri, D., Melançon, D., Miaux, Y., Rippon, G., Black, R., Lu, Y., Brashear, H. R., Arrighi, H. M., Morris, K. A., & Grundman, M. (2013). MR Imaging Features of Amyloid-Related Imaging Abnormalities. American Journal of Neuroradiology. https://doi.org/10.3174/ajnr.a3500

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.