Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 167

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Impact of Modified TICI 3 versus Modified TICI 2b Reperfusion Score to Predict Good Outcome following Endovascular Therapy

Open access
Dargazanli, C., Consoli, A., Barral, M., Labreuche, J., Redjem, H., Ciccio, G., Smajda, S., Desilles, J.P., Taylor, G., Preda, C., Coskun, O., Rodesch, G., Piotin, M., Blanc, R., Lapergue, B. · 2017 · American Journal of Neuroradiology

Abstract

BACKGROUND AND PURPOSE: The TICI score is widely used to evaluate cerebral perfusion before and after the endovascular treatment of stroke. Recent studies showing the effectiveness and safety of mechanical thrombectomy combine modified TICI 2b and modified TICI 3 to assess the technical success of endovascular treatment. The purpose of this study was to determine how much clinical outcomes differ between patients achieving modified TICI 2b and modified TICI 3 reperfusion. MATERIALS AND METHODS: We analyzed 222 consecutive patients with acute large intracranial artery occlusion of the anterior circulation having achieved modified TICI 2b or modified TICI 3 reperfusion after thrombectomy. The primary end point was the rate of favorable outcome defined as the achievement of a modified Rankin Scale score of 0-2 at 3 months. RESULTS: Patients with modified TICI 3 more often had favorable collateral circulation and atherosclerosis etiology, with a shorter time from onset to reperfusion than patients with modified TICI 2b (all P < .05). The number of total passes to achieve reperfusion was higher in the modified TICI 2b group (median, 2; interquartile range, 1-3, 1-9) versus (median, 1; interquartile range, 1-2, 1-8) in the modified TICI 3 group (P = .0002). Favorable outcome was reached more often for patients with modified TICI 3 than for those with modified TICI 2b (71.7% versus 50.5%, P = .001), with a similar difference when considering excellent outcome. In addition, patients with modified TICI 3 had a lower intracerebral hemorrhage rate (23.0% versus 45.0%, P < .001). CONCLUSIONS: Patients with modified TICI 3 reperfusion have better functional outcomes than those with modified TICI 2b. Given the improving reperfusion rates obtained with thrombectomy devices, future thrombectomy trials should consider modified TICI 2b and modified TICI 3 status separately.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3174/ajnr.a4968

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 167

Metadata

Authors
Dargazanli, C., Consoli, A., Barral, M., Labreuche, J., Redjem, H., Ciccio, G., Smajda, S., Desilles, J. P., Taylor, G., Preda, C., Coskun, O., Rodesch, G., Piotin, M., Blanc, R., & Lapergue, B.
Venue
American Journal of Neuroradiology
Published
2016-11-03
Volume
38
Issue
1
Pages
90-96
ISSN
  • 0195-6108 (ISSN-L)
  • 1936-959X
OpenAlex
W2548480032
Cited by
167
References
1
FWCI
14.72
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Impact of Modified TICI 3 versus Modified TICI 2b Reperfusion Score to Predict Good Outcome following Endovascular Therapy. https://app.cochat.ai/papers/10.3174/ajnr.a4968
The paper
Dargazanli, C., Consoli, A., Barral, M., Labreuche, J., Redjem, H., Ciccio, G., Smajda, S., Desilles, J. P., Taylor, G., Preda, C., Coskun, O., Rodesch, G., Piotin, M., Blanc, R., & Lapergue, B. (2017). Impact of Modified TICI 3 versus Modified TICI 2b Reperfusion Score to Predict Good Outcome following Endovascular Therapy. American Journal of Neuroradiology. https://doi.org/10.3174/ajnr.a4968

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.