Cited by 110Advanced Neuroimaging Techniques and ApplicationsAdvanced MRI Techniques and ApplicationsFunctional Brain Connectivity Studies

Toward precision and reproducibility of diffusion tensor imaging: a multicenter diffusion phantom and traveling volunteer study

Open access
Palacios, E.M., Martin, A.J., Boss, M.A., Ezekiel, F., Chang, Y.S., Yuh, E.L., Vassar, M.J., Schnyer, D.M. +5 more·2017·American Journal of Neuroradiology

Abstract

BACKGROUND AND PURPOSE: Precision medicine is an approach to disease diagnosis, treatment, and prevention that relies on quantitative biomarkers that minimize the variability of individual patient measurements. The aim of this study was to assess the intersite variability after harmonization of a high-angular-resolution 3T diffusion tensor imaging protocol across 13 scanners at the 11 academic medical centers participating in the Transforming Research and Clinical Knowledge in Traumatic Brain Injury multisite study. MATERIALS AND METHODS: Diffusion MR imaging was acquired from a novel isotropic diffusion phantom developed at the National Institute of Standards and Technology and from the brain of a traveling volunteer on thirteen 3T MR imaging scanners representing 3 major vendors (GE Healthcare, Philips Healthcare, and Siemens). Means of the DTI parameters and their coefficients of variation across scanners were calculated for each DTI metric and white matter tract. RESULTS: /s. For the volunteer, the coefficients of variations across scanners of the 4 primary DTI metrics, each averaged over the entire white matter skeleton, were all <5%. In individual white matter tracts, large central pathways showed good reproducibility with the coefficients of variation consistently below 5%. However, smaller tracts showed more variability, with the coefficients of variation of some DTI metrics reaching 10%. CONCLUSIONS: The results suggest the feasibility of standardizing DTI across 3T scanners from different MR imaging vendors in a large-scale neuroimaging research study.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3174/ajnr.a5025

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 30 · Cited by 110

Research works printed but not linked: 28

  1. [2]Niogi SN Mukherjee P Ghajar J Extent of microstructural white matter injury in postconcussive syndrome correlates with impaired cognitive reaction time: a 3T diffusion tensor imaging study of mild traumatic brain injury AJNR Am J Neuroradiol 2008 5 967 73 PMC8128563 18272556
  2. [3]Newcombe V Chatfield D Outtrim J Mapping traumatic axonal injury using diffusion tensor imaging: correlations with functional outcome PLoS One 2011 6 e19214 21573228 PMC3087728
  3. [4]Palacios EM Sala-Llonch R Junque C White matter integrity related to functional working memory networks in traumatic brain injury Neurology 2012 78 852 60 22345222
  4. [5]Yuh EL Cooper SR Mukherjee P Diffusion tensor imaging for outcome prediction in mild traumatic brain injury: a TRACK-TBI study J Neurotrauma 2014 31 1457 77 24742275 PMC4144386
  5. [6]Yue JK Vassar MJ Lingsma HF Transforming research and clinical knowledge in traumatic brain injury pilot: multicenter implementation of the common data elements for traumatic brain injury J Neurotrauma 2013 30 1831 44 23815563 PMC3814815
  6. [7]Hsu W Markey MK Wang MD Biomedical imaging informatics in the era of precision medicine: progress, challenges, and opportunities J Am Med Inform Assoc 2013 20 1010 3 24114330 PMC3822124
  7. [8]Walker L Curry M Nayak A A framework for the analysis of phantom data in multicenter diffusion tensor imaging studies Hum Brain Mapp 2013 34 2439 54 22461391 PMC3458186
  8. [9]Pagani E Hirsch JG Pouwels PJ Intercenter differences in diffusion tensor MRI acquisition J Magn Reson Imaging 2010 31 1458 68 20512899
  9. [10]Vollmar C O’Muircheartaigh J Barker GJ Identical, but not the same: intra-site and inter-site reproducibility of fractional anisotropy measures on two 3. 0T scanners Neuroimage 2010 51 1384 94 20338248 PMC3163823
  10. [11]Jansen JF Kooi ME Kessels AG Reproducibility of quantitative cerebral T2 relaxometry, diffusion tensor imaging, and 1H magnetic resonance spectroscopy at 3. 0 Tesla Invest Radiol 2007 42 327 37 17507802
  11. [12]Bisdas S Bohning DE Besenski N Reproducibility, interrater agreement, and age-related changes of fractional anisotropy measures at 3T in healthy subjects: effect of the applied b-value AJNR Am J Neuroradiol 2008 29 1128 33 18372415 PMC8118811
  12. [13]Takao H Hayashi N Kabasawa H Ohtomo K Effect of scanner in longitudinal diffusion tensor imaging studies Hum Brain Mapp 2012 33 466 77 21391276 PMC6869949
  13. [14]Magnotta VA Matsui JT Liu D Multicenter reliability of diffusion tensor imaging Brain Connect 2012 2 345 55 23075313 PMC3623569
  14. [15]Huang L Wang X Baliki MN Wang L Apkarian AV Parrish TB Reproducibility of structural, resting-state BOLD and DTI data between identical scanners PLoS One 2012 7 e47684 23133518 PMC3485040
  15. [16]Veenith TV Carter E Grossac J Inter subject variability and reproducibility of diffusion tensor imaging within and between different imaging sessions PLoS One 2013 8 e65941 23840380 PMC3696006
  16. [17]Kamagata K Shimoji K Hori M Intersite Reliability of Diffusion Tensor Imaging on Two 3T Scanners Magn Reson Med Sci 2015 14 227 33 25740241
  17. [18]Polders DL Leemans A Hendrikse J Signal to noise ratio and uncertainty in diffusion tensor imaging at 1.5, 3.0, and 7. 0 Tesla J Magn Reson Imaging 2011 33 1456 63 21591016
  18. [20]Mirzaalian H Pierrefeu A Savadjiev P Harmonizing diffusion MRI data across multiple sites and scanners MICCAI 2015 PMC5045042 27754499
  19. [21]Zhu T Hu R Qiu X Quantification of accuracy and precision of multi-cente DTI measurements: a diffusion phantom and human brain study Neuroimage 2011 56 1398 411 21316471 PMC3085553
  20. [22]Grech-Sollars M Hales PW Miyazaki K Multi-centre reproducibility of diffusion MRI parameters for clinical sequences in the brain NMR Biomed 2015 28 468 85 25802212 PMC4403968
  21. [23]Mukherjee P Berman JI Chung SW Hess CP Henry RG Diffusion tensor MR imaging and fiber tractography: theoretic underpinnings AJNR Am J Neuroradiol 2008 29 632 641 18339720 PMC7978191
  22. [24]Mukherjee P Chung SW Berman JI Hess CP Henry RG Diffusion tensor MR imaging and fiber tractography: technical considerations AJNR Am J Neuroradiol 2008 29 843 852 18339719 PMC8128579
  23. [26]Behrens TE Johansen-Berg H Woolrich MW Non-invasive mapping of connections between human thalamus and cortex using diffusion imaging Nat Neurosci 2003 6 750 7 12808459
  24. [27]Smith SM Jenkinson M Johansen-Berg H Tract-based spatial statistics: voxelwise analysis of multi-subject diffusion data Neuroimage 2006 31 1487 505 16624579
  25. [28]Smith SM Jenkinson M Woolrich MW Advances in functional and structural MR image analysis and implementation as FSL Neuroimage 2004 23 Suppl 1 S208 19 15501092
  26. [30]Galanaud D Perlbarg V Gupta R Assessment of white matter injury and outcome in severe brain trauma: a prospective multicenter cohort Anesthesiology 2012 117 1300 1310 23135261
  27. [31]Dinkel J Drier A Khalilzadeh O Long-term white matter changes after severe traumatic brain injury: a 5-year prospective cohort AJNR Am J Neuroradiol 2014 35 23 29 23846796 PMC7966468
  28. [32]Venkatraman VK Gonzalez CE Landman B Region of interest correction factors improve reliability of diffusion imaging measures within and across scanners and field strengths Neuroimage 2015 119 406 16 26146196 PMC5519407

Authors
Palacios, E. M., Martin, A. J., Boss, M. A., Ezekiel, F., Chang, Y. S., Yuh, E. L., Vassar, M. J., Schnyer, D. M., MacDonald, C. L., Crawford, K. L., Irimia, A., Toga, A. W., & Mukherjee, P.
Affiliations
  • National Institute of Standards and Technology (US)
  • San Francisco General Hospital (US)
  • The University of Texas at Austin (US)
  • University of Washington (US)
  • University of Southern California (US)
Venue
American Journal of Neuroradiology
Published
2016-12-22
Volume
38
Issue
3
Pages
537-545
ISSN
  • 0195-6108 (ISSN-L)
  • 1936-959X
OpenAlex
W2567143195
Cited by
110
References
30
Citations by year
2026: 4 · 2025: 10 · 2024: 5 · 2023: 9 · 2022: 18 · 2021: 16 · 2020: 9 · 2019: 14 · 2018: 12 · 2017: 11 · 2012: 1
FWCI
10.71
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • American Journal of Neuroradiology (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
  • eScholarship (California Digital Library) (submittedVersion)
Funders
  • Alzheimer's Association
  • University of Southern California
  • Radiological Society of North America
  • University of Washington
  • Quest Diagnostics
  • Voyager Therapeutics
  • National Institutes of Health (-0001, W81XWH)
  • National Institute of Standards and Technology
  • National Institute on Aging (R01AG046460)
  • National Institute of Mental Health (R24MH106096, R01MH094343)
  • National Cancer Institute (R01CA194533, R21CA186140)
  • National Institute of Neurological Disorders and Stroke (R44NS081792, R01NS060776, U01NS086090)
  • National Institute of Biomedical Imaging and Bioengineering (R01EB012031, P41EB015922)
  • Eunice Kennedy Shriver National Institute of Child Health and Human Development (R01HD072074, R01HD031526)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced Neuroimaging Techniques and Applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Functional Brain Connectivity Studies
Keywords
diffusion tensor imaging, reproducibility, diffusion phantom, white matter tracts, traumatic brain injury, precision medicine
MeSH terms
Brain, Humans, Volunteers, Reproducibility of Results, Phantoms, Imaging, Diffusion Tensor Imaging, Neuroimaging

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review